IBM System x3300 M4 power part numbers.
Content
- See ServerProven for power compatibility
- See Configuration and Options Guide (COG) for all parts that are configurable with this system
| Description | Marketing part number | Replacement part number | CRU/FRU |
|---|---|---|---|
| UPS | |||
| UPS 1000T LV | 2130R3X | 90P4820 | |
| UPS 1000T HV | 2130R4X | 90P4821 | |
| UPS 1500T LV | 2130R5X | 90P4819 | |
| UPS 7500 XHV | 21303RX | MultiFRU | |
| UPS 1500T HV | 2130R6X | 90P4822 | |
| UPS 10000 XHV | 21304RX | MultiFRU | |
| UPS 1000T JV | 2130R8X | 90P4824 | |
| UPS 1500T JV | 2130R9X | 90P4825 | |
| UPS5000 | 24195KX | N/A | |
| Power Supply | |||
| System x 550 W High Efficiency Platinum AC | 94Y5975 | 81Y6074 | |
| System x 750 W High Efficiency Platinum AC | 94Y5974 | 43X3314 | |
| Other | |||
| System x Redundant Power and Cooling Option | 44X0381 | 44X0381 | |
| Redundant Cooling Upgrade Kit | 81Y7007 | 81Y6084 | |
| Redundant System FAN | 00D2593 | 94Y7447 | |
| Rack Power Cable | |||
| 4.3m, 10A or 120 V, C13 to NEMA 5-15P (US) | 39Y7931 | 6207 | |
| 4.3m, 10A or 100-250 V, C13 to IEC 320-C14 | 39Y7932 | 6263 | |
| 1.5m, 10A or 100-250 V, C13 to IEC 320-C14 | 39Y7937 | 6201 | |
| 2.8m, 10A or 100-250 V, C13 to IEC 320-C20 | 39Y7938 | 6204 | |
| Active Energy Manager PDU | |||
| 1U 9 C19/3 C13 Active Energy Manager DPI PDU | 46M4002 | 46M4014 | |
| 1U 9 C19/3 C13 Active Energy Manager 60A 3 Phase PDU | 46M4003 | 46M4015 | |
| 1U 12 C13 Active Energy Manager DPI PDU | 46M4004 | 46M4016 | |
| 1U 12 C13 Active Energy Manager 60A 3 Phase PDU | 46M4005 | 46M4017 | |
| 0U 24 C13 Switched and Monitored 30A PDU | 46M4116 | 46W1561 | |
| Power distribution units | |||
| 0U 24 C13 30A 3 Phase PDU | 46M4125 | 46W1567 | |
| 0U 12 C19/12 C13 50A 3 Phase PDU | 46M4140 | 46W1577 | |
| 0U 24 C13 30A PDU | 46M4128 | 46W1569 | |
| 0U 12 C19/12 C13 Switched and Monitored 50A 3 Phase PDU | 46M4134 | 46W1573 | |
| 1U 9 C19/3 C13 Switched and Monitored 30A 3 Phase PDU | 46M4167 | 46W1581 | |
| 30 amp or 125 V Front-end PDU with NEMA L5-30P connector | 39Y8938 | N/A | |
| 30 amp or 250 V Front-end PDU with NEMA L6-30P connector | 39Y8939 | N/A | |
| 60 amp or 250 V Front-end PDU with IEC 309 60A 2P+N+Gnd connector | 39Y8940 | N/A | |
| DPI NEMA Rack PDU | 39Y8905 | N/A | |
| DPI 60 A Three Phase C19 Enterprise PDU w/ IEC309 3P+G (208 V) fixed line cord | 39Y8923 | 39Y8926 | |
| DPI Single Phase C13 Enterprise PDU w/o line cord | 39Y8941 | N/A | |
| DPI Single Phase C19 Enterprise PDU w/o line cord | 39Y8948 | N/A | |
| DPI Universal Rack PDU w/ Nema L5-20P & L6-20P (US cord) | 39Y8951 | N/A | |
| DPI C13 PDU+C13 without linecord | 39M2816 | ||
| Ultra Density Enterprise PDU | |||
| C19 PDU (WW) | 71762NX | 43V5981 | |
| C19 3 phase 60A PDU+ (NA) | 71763MU | 43V5980 | |
| C19 3 phase 60A PDU (NA) | 71763NU | 43V5982 | |
| LCD | |||
| LCD UPS Network Management Card | 46M4110 | 6145 | |
| 1500 VA LCD 2U Rack UPS (100 V or 120 V) | 53951xx | N/A | |
| 2200 VA LCD 2U Rack UPS (100 V or 120 V) | 53952xx | N/A | |
| 3000 VA LCD 3U Rack UPS (100 V or 120 V) | 53953AX | N/A | |
| 3000 VA LCD 3U Rack UPS (200 V or 208 V) | 53953JX | N/A | |
| 6000 VA LCD 4U Rack UPS (200 V or 208 V) | 53956AX | N/A | |
| 11000 VA LCD 5U Rack UPS (230 V) | 53959KX | N/A | |
| Tower UPS | |||
| IBM 1000VA LCD Tower UPS (120V) | 53961xx | N/A | |
| IBM 1500VA LCD Tower UPS (120V) | 53962xx | N/A | |
Document Location
Worldwide
[{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWXB8","label":"Lenovo x86 servers->Lenovo System x3300 M4"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWXG4","label":"System x->System x3300 M4"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]