Text from the audio portion of the replacing the battery movie

To remove the cover:

  1. Turn off the server and all attached peripheral devices.
  2. Disconnect all power cords; then, disconnect all external signal cables from the server.
  3. Remove the server from the rack.
  4. Then, lift the cover release latch; slide the cover to the rear, lift up the front of the cover, and then lift off the cover.

To remove the battery:

  1. Lift the PCI shield to gain access to the battery on the system board
  2. Press on the tab to release the battery from its housing.
  3. Use one finger to slide the battery up and out from its socket.
  4. Insert the new battery with the larger side facing up and press it down until it latches into place.

To install the cover:
Position the cover on the chassis, and close the latch.

Turn on the server, start the Configuration/Setup Utility program, and set configuration parameters:

Set the system date and time and set the power-on password.

 