Question
File System Adapter halts with error ?modification time under limit - not collected? *|* -FB5C4526A68AD5E78525791700791DF7- *|*
Answer
Technote (troubleshooting)
Problem(Abstract)
File System Adapter halts with error &modification time under limit - not collected?
Symptom
File System Adapter halts with error ?modification time under limit - not collected?.
This occurs when these parameters are set:
?? nofilesSetsuccess???? set to? 'Yes'
?? collectmultiple?????? set to? 'Yes'
The 'nofilessetsuccess' parameter not honoured if the ?collectmultiple? parameter is set to true.
Resolving the problem
Please apply Gentran Integration Suite Release 4.1.1 Build?1986 or later.
Please apply Gentran Integration Suite Release 4.2 Build?4211 or later.
Please apply Gentran Integration Suite Release 4.3 Build 4306 or later.
| Segment | Product | Component | Platform | Version | Edition |
|---|---|---|---|---|---|
| Commerce | Sterling B2B Integrator | Adapters |
Historical Number
NFX1904
Product Alias/Synonym
Function Area
Adapters - File System
Escalation ID
1368343
Fix ID
42092 42090 42091
Severity
Normal
Type
NormalFix
Build
4306 1986 4211
Was this topic helpful?