Question & Answer
Question
How to Process an EDI Document with a BIN (Binary) Segment in Gentran Server for Windows and its Application Integration Mapper *|* -EBC586EC7A4E6D89852579190007DFA8- *|*
Answer
Technote (FAQ)
Question
How to Process an EDI Document with a BIN (Binary) Segment in Gentran Server for Windows and its Application Integration Mapper
Answer
Follow the steps below to process (Inbound) an EDI document containing a BIN Segment with Binary data:
- In the Application Ingtegration Map right-click on the BIN segment and go to Properties.
- Click on the Special Tab and place a checkmark for Binary.
- Right click on the LENGTH OF BINARY DATA element and select Properties.
- Click on the Validation Tab and set the data-type dropdown to 'Bin Len.'
- Right click on the BINARY DATA element and select Properties.
- Click on the Validation Tab and set the data-type dropdown to 'Bin Data.'
Continue the normal development of this map then Save Compile Register and Associate with a Partner Profile.
- In the GENTRAN GUI go to Tools-->Configuration and select the Splitter Tab.
- Type the name of the Segment in the field called "Name of Binary Segment That Gentran Should Look For." Typcally the value is BIN.
- Save out of the Configuration view.
At this point the Inbound EDI file may by translated. The output of the BIN segment will be in the :\GENSRVNT\IntIn directory with a .bin extension. The EDI portion will also be in the IntIn with a .int extension. Note that the system file names for both the .int and .bin files will be alike.
Fact
Gentran:Server for Windows All Releases above 4.0.02
Note
Not available for ODBC and Positional maps. Contact support to open a new Enhancement Request as needed.
Needed for common HIPAA Transactions 275 and 841.
Goal
How to Process an EDI Document with a BIN (Binary) Segment in Gentran Server for Windows and its Application Integration Mapper
Historical Number
HTG3240