Troubleshooting
Problem
This technote explains how to resolve an ordinal 6880 error, that might occur when using IBM® Rational® Robot.
Symptom
The ordinal 6880 could not be located in the dynamic link library MFC42.dll - error message occurs when playing back a Robot GUI script against a PeopleSoft / PeopleTools Application.
The ordinal 6880 could not be located in the dynamic link library MFC42.dll
Resolving The Problem
Typically, the solution to this error message is to rename all copies of the MFC42.dll on the affected computer, except for the version in C:\Windows\System 32. Or, if the file version of the MFC42.dll in C:\Windows\System 32 is not 6.xxx or later, to update the MFC42.dll.
If this does not resolve the issue, try the following:
- Open Robot.
- Click Tools -> Extension Manager.
- Check the PeopleTools option if it is not already checked.
- Uncheck every other option that is checked.
Historical Number
111035124
Was this topic helpful?
Document Information
Modified date:
16 June 2018
UID