Troubleshooting
Problem
A known issue affects IBM Guardium appliances with FIPS mode enabled running the following releases:
- For 12.2 environments: 12.0p220 and earlier
- For 12.1 environments: 12.0p140 and earlier
- For 12.0 environment: 12.0p55 and earlier
The Java SDK included in these releases has expired. As a result, GUI services may fail to start, causing the Guardium UI to become inaccessible.
Symptom
Guardium GUI to become inaccessible
Cause
The embedded Java SDK used by the Guardium GUI in FIPS-enabled environments reached its expiration date, preventing the GUI components from starting correctly.
Environment
- Guardium appliances with FIPS mode enabled.
- Affected environments:
- For 12.2 environments: 12.0p220 and earlier
- For 12.1 environments: 12.0p140 and earlier
- For 12.0 environment: 12.0p55 and earlier
Diagnosing The Problem
The issue may be present if all the following conditions are met:
- The appliance is running Guardium Appliances Running v12.0p220 or Earlier, v12.0p140 or Earlier, v12.0p55 or Earlier
- FIPS mode is enabled on the appliance.
- Users are unable to access the Guardium GUI.
Symptoms
- The Guardium web interface fails to load or displays an error.
- GUI-related services fail to start successfully.
- Administrative access through the GUI is unavailable, while other appliance functions may continue to operate.
Verification
Run the following command to determine whether FIPS is enabled as a CLI command on Guardium appliance: show system fips
xxxx.com> show system fipsmode
FIPS mode is DISABLED on this system.
ok
Resolving The Problem
To remediate this issue, perform the following steps:
- Disable FIPS mode on the affected Guardium appliance. Using the cli command: store system fipsmode off
- Install the latest Guardium Health Check package to verify the system's readiness for upgrade and identify any potential issues.
- Upgrade the appliance to a fixed release, one of the following:
- Guardium 12.0p60 or later
- Guardium 12.0p145 or later
- Guardium 12.2.3 (12.0p230) or later
- After the upgrade completes successfully, re-enable FIPS mode. Using the cli command: store system fipsmode on
- Verify that the Guardium GUI is accessible and operating normally.
Document Location
Worldwide
[{"Type":"MASTER","Line of Business":{"code":"LOB76","label":"Data Platform"},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSMPHH","label":"IBM Security Guardium"},"ARM Category":[{"code":"a8m0z000000Gp0JAAS","label":"APPLIANCE"}],"ARM Case Number":"","Platform":[{"code":"PF004","label":"Appliance"}],"Version":"12.0.0;12.1.0;12.2.0;12.2.1;12.2.2"}]