IBM Support

IBM Guardium Key Lifecycle Manager version 5.1.0.0 startup failure in FIPS 140-3 mode after September 21, 2026

General Page

If you are using IBM Security Guardium Key Lifecycle Manager version 5.1.0.0 (without any Fix Pack applied) and running with FIPS 140-3 mode enabled, you may experience a server startup failure when you restart Guardium Key Lifecycle Manager server after September 21, 2026.
As a result, the Guardium Key Lifecycle Manager server remains unavailable until corrective action is taken.

Affected domain

  • Guardium Key Lifecycle Manager version 5.1.0.0 (no Fix Pack installed)
  • FIPS 140-3 mode enabled
  • Server restart performed on or after September 21, 2026

Cause

The Guardium Key Lifecycle Manager startup failure is caused by the Semeru JVM's FIPS compliance enforcement rejecting an expired FIPS certificate reference (CMVP Certificate #4755) in the active Restricted Security profile.

The issue occurs because IBM Semeru Runtime 21 uses the Restricted Security framework (openj9.internal.security.RestrictedSecurity) to enforce FIPS compliance. When FIPS mode is enabled, the JVM validates the expiration status of the FIPS-certified cryptographic module referenced by the active security profile. The profile in use references NIST CMVP Certificate #4755 (IBM Crypto for C v8.8.1.0), which reached its sunset date on September 21, 2026. After NIST moved certificate #4755 to Historical status and replaced it with certificate #5486, the Semeru JVM detected that the configured FIPS certificate had expired and terminated during startup by invoking System.exit(). 

As a result, the JVM could not start and no application code, including Guardium Key Lifecycle Manager, was able to run, resulting in the error:

[{"Type":"MASTER","Line of Business":{"code":"LOB76","label":"Data Platform"},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSWPVP","label":"IBM Guardium Key Lifecycle Manager"},"ARM Category":[{"code":"a8m0z000000cvdLAAQ","label":"SKLM"}],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0"}]

Document Information

Modified date:
13 October 2026

UID

ibm17292220