IBM Support

IBM i 7.6 TR2 / 7.5 TR8 -- Virtual Ethernet Connectivity Advisory

Flashes (Alerts)


Abstract

IBM is investigating a network connectivity issue that can affect IBM i 7.6 TR2 and 7.5 TR8 systems using Virtual Ethernet adapter type 268C

Content

Document last updated 10/2/26 

 

Issue Overview

IBM is currently investigating a reported issue affecting systems running IBM i 7.6 TR2 or IBM i 7.5 TR8. Installing the Technology Refresh (TR) can cause a complete loss of network connectivity on partitions using Virtual Ethernet adapter type 268C. IBM is actively working to identify the root cause and appropriate corrective action.

Affected Environments

This issue affects:

  • IBM i 7.5 TR8 systems using Virtual Ethernet adapter type 268C

  • IBM i 7.6 TR2 systems using Virtual Ethernet adapter type 268C

If your environment includes either of the above configurations, please review the recommended actions below.


 

What's the Impact

Affected virtual ethernet adapters experience a complete loss of network connectivity, resulting in:

  • Possible loss of remote access to the partition

  • Application connectivity failures

  • Service interruptions affecting dependent systems

  • Reduced ability to remotely manage, monitor, or administer the system


 

Recommended Actions

 

Development has identified the root cause of the issue and has released the following HIPER PTFs to address it.

Note: The following fixing PTFs are expected to be available for download on 10/03/2026 to resolve the Virtual Ethernet issue:

  • IBM i 7.5: MJ11725
  • IBM i 7.6: MJ11726

Please download the appropriate PTF for your IBM i release and apply it along with the cumulative package and group PTFs that contain TR8 (IBM i 7.5) or TR2 (IBM i 7.6).

The fixing PTFs have a prerequisite of TR8 for IBM i 7.5 and TR2 for IBM i 7.6. Systems that do not already have the required Technology Refresh installed will require an IPL as part of the update process.

If your system has encountered this issue, apply the corresponding fixing PTF once it becomes available.

 

[{"Type":"MASTER","Line of Business":{"code":"LOB68","label":"Power HW"},"Business Unit":{"code":"BU070","label":"IBM Infrastructure"},"Product":{"code":"SWG60","label":"IBM i"},"ARM Category":[{"code":"a8m0z0000000CJlAAM","label":"Communications-\u003EEthernet Virtual Token Ring"}],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.5.0;7.6.0"}]