IBM Support

PH73216: HALOAD MAY INCORRECTLY CONTINUE TIMEOUT PROCESSING CAUSING THE LOAD JOB TO BE CANCELED, JOB TERMINATION TO BE DELAYED OR HANG

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • HALOAD health monitor may incorrectly continue timeout
    processing instead of being reset, causing the load job to be
    canceled and job termination to be delayed or hang.
    
    1. When HALOAD job is configured to load data to one
    accelerator or more than one accelerator(s), the load job may
    fail with the following messages:
    HLOU5738I <day of year> <time> ACCEL_LOAD_TABLES stored
    procedure ended on <accelerator> , RC=0014
    The job continues processing and reports successful load
    completion messages such as:
    HLOU4004I <day of year> <time> Task: nn, Load completed for
    table: <table name>, partition: nn
    
    However, after the HLOU4004I message is issued, the health
    monitor timeout countdown may continue instead of being reset.
    When the timeout expires, the health monitor incorrectly assumes
    that no load activity has occurred, cancels the active load job,
    and issues messages similar to the following:
    HLOU5931I <day of year> <time> No load activity detected.
    Timeout expired nn seconds. Timeout remaining 0 seconds
    HLOU5935E <day of year> <time> ACCEL_LOAD_TABLES on accelerator
    <accelerator> canceled by HLOUHMON. Reason code 2
    HLOU5738I <day of year> <time> ACCEL_LOAD_TABLES stored
    procedure ended on <accelerator> , RC=0007
    
    OR
    
    HLOU5931I <day of year> <time> No load activity detected.
    Timeout expired nn seconds. Timeout remaining 0 seconds
    HLOU5935E <day of year> <time> ACCEL_LOAD_TABLES on accelerator
    <accelerator> canceled by HLOUHMON. Reason code 3
    HLOU5738I <day of year> <time> ACCEL_LOAD_TABLES stored
    procedure ended on <accelerator> , RC=0007
    
    When the health monitor cancels a job, job termination can be
    significantly delayed. Sometimes the cancellation process may
    not complete successfully, causing the job to hang.
    
    This APAR introduces the following improvements:
    -The health monitor timeout countdown is now reset when there is
    progress in load. As a result, the timeout count down processing
    no longer continues after valid load activity is detected.
    -Health monitor cancellation processing has been modified,
    enabling canceled jobs to terminate more quickly and avoid
    hangs.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Users                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: HALOAD health monitor may incorrectly   *
    *                      continue timeout processing instead of  *
    *                      being reset, causing the load job to    *
    *                      be canceled and job termination to be   *
    *                      delayed or hang.                        *
    ****************************************************************
    HALOAD health monitor may incorrectly continue timeout
    processing instead of being reset, causing the load job to be
    canceled and job termination to be delayed or hang.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PH73216

  • Reported component name

    IDAA LOADER ZOS

  • Reported component ID

    5639OLA00

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2026-09-16

  • Closed date

    2026-11-11

  • Last modified date

    2026-11-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UO10353

Modules/Macros

  • HLO#A001 HLO#ACIR HLO#ACIW HLO#ACON HLO#ACRD HLO#ACUP HLO#ADIS
    HLO#ADSC HLO#AEXT HLO#AFMT HLO#AFRR HLO#ALLO HLO#AMIN HLO#ASYS
    HLO#AUMX HLO#BIND HLO#CARD HLO#CHKR HLO#CL64 HLO#CLLS HLO#CMTS
    HLO#CNTL HLO#CPNT HLO#CPOL HLO#DSAF HLO#DSPL HLO#DYNL HLO#ENCR
    HLO#ENQS HLO#ENVF HLO#FCPY HLO#ICAI HLO#ICAL HLO#ICCC HLO#ICCI
    HLO#IDCF HLO#IDSA HLO#IERR HLO#IHSA HLO#IKPL HLO#IKPN HLO#ILGP
    HLO#ILRA HLO#ILRS HLO#ILSA HLO#INIT HLO#IPIE HLO#IPPB HLO#IPPC
    HLO#IPPD HLO#IPPH HLO#IPPL HLO#IPPN HLO#IPPS HLO#IRPL HLO#ISNA
    HLO#LGAA HLO#LGAC HLO#LGAF HLO#LGAI HLO#LGAP HLO#LOGR HLO#LRD6
    HLO#MAIN HLO#MDRV HLO#MLOG HLO#MMGR HLO#MREP HLO#MTIO HLO#NREC
    HLO#OS   HLO#PRNG HLO#PRSE HLO#QSAM HLO#RANG HLO#RPRP HLO#RUNT
    HLO#STAT HLO#SUBD HLO#SUBX HLO#SYSC HLO#TUTL HLO#UTLS HLO#VERS
    HLO#VSM  HLO#WRIT HLO#XMLI HLO#XMLJ HLO#XMLS HLO$ACCS HLO$ACES
    HLO$ADMN HLO@CFUP HLOADDTB HLOAPOST HLOBLNKT HLOCAPST HLOCLBK1
    HLOCLBK2 HLOCOMAT HLOEDIT  HLOFTRT  HLOHEXT  HLOIENQS HLOLGRD
    HLOLVALT HLOMMGR  HLOMSGEN HLONBLKT HLONNUMT HLOPACEL HLOPAOBK
    HLOPARET HLOPCHCK HLOPCOPY HLOPDITB HLOPDOBJ HLOPERIT HLOPEXEC
    HLOPEXPR HLOPFILE HLOPFSPC HLOPHALO HLOPIPE  HLOPIPEA HLOPIPEG
    HLOPLINE HLOPLIST HLOPLOAD HLOPMSG  HLOPMSGI HLOPOPTS HLOPOSGS
    HLOPOSRV HLOPPFLE HLOPPRSE HLOPPSTR HLOPQUIS HLOPREBU HLOPRECO
    HLOPREOR HLOPRPG  HLOPRUNS HLOPSCNV HLOPSTMT HLOPSTPR HLOPSTRG
    HLOPSYSR HLOPTMPL HLOPUNLD HLOPUTLM HLOPUTLU HLOPUTLX HLORBKU1
    HLORDELD HLOREBD  HLOREEXP HLORERD  HLORUSQA HLORUSQL HLOS99
    HLOSINIT HLOSMEPL HLOSTDB2 HLOSUSQA HLOSUSQL HLOUBKU1 HLOUCBAS
    HLOUCOPY HLOUDELD HLOUFSPC HLOUGACG HLOUHAL1 HLOUHLTP HLOUHMON
    HLOUHTMG HLOUMAIN HLOUMEPL HLOUNTOK HLOUSE15 HLOUSE35 HLOUTMGR
    HLOUUMON HLOZSCHD HLOZSRB3
    

Fix information

  • Fixed component name

    IDAA LOADER ZOS

  • Fixed component ID

    5639OLA00

Applicable component levels

  • R310 PSY UO10353

       UP26/11/13 I 1000 ­

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
17 November 2026