A fix is available
APAR status
Closed as program error.
Error description
Enterprise COBOL V6.5 generates SYSADATA as RECFM=VB, but some records have non-zero RDW (Record Descriptor Word) bytes 3-4 (ZZ Bytes), where VB records are expected to have zeroes. The SYSADATA header and records after the RDW is valid and intact. This does not affect the content or use of SYSADATA files outside of any third party applications which verify the RDW is correct.
Local fix
Apply the IBM provided PTF
Problem summary
**************************************************************** * USERS AFFECTED: All users of the Enterprise COBOL 6.4 * * compiler who are compiling with the * * SYSADATA option, and after compiling, * * inspect bytes 3 and 4 of the 4-byte Record * * Descriptor Word (RDW) fields of the * * SYSADATA data set. * **************************************************************** * PROBLEM DESCRIPTION: Bytes 3 and 4 of the RDW may be * * non-zero. This problem does not * * prevent the compiler user from using * * or processing the SYSADATA data set. * * The SYSADATA header information * * remains accurate and the data * * contained in the data set records is * * unaffected. * **************************************************************** * RECOMMENDATION: Apply the IBM provided PTF * **************************************************************** Enterprise COBOL 6.5 generates SYSADATA as RECFM=VB, but some records have non-zero RDW (Record Descriptor Word) bytes 3-4 (ZZ Bytes), where VB records are expected to have zeroes. The SYSADATA header and records after the RDW is valid and intact. This does not affect the content or use of SYSADATA files outside of any third party applications which verify the RDW is correct.
Problem conclusion
The Record Descriptor Word for the RECFM=VB SYSADATA data set was stored in two variables, one for bytes 1-2 of the RDW containing the actual length of the variable length record, and a second variable for bytes 3-4 which was not required but was also not initialized. The compiler has been updated so that bytes 3-4 of the RDW is always initialized to zero, before the record is written to the SYSADATA data set.
Temporary fix
Comments
APAR Information
APAR number
PH72491
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
640
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2026-07-30
Closed date
2026-07-30
Last modified date
2026-09-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UO08817 UO08818 UO08819 UO08820
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCJBLD IGYCJGEN IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOB2 IGYCOB2E IGYCOPI IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R640 PSY UO08817
UP26/08/29 P F608
R641 PSY UO08818
UP26/08/29 P F608
R642 PSY UO08819
UP26/08/29 P F608
R64H PSY UO08820
UP26/08/29 P F608
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"640","Line of Business":{"code":"LOB70","label":"Z TPS"}}]
Document Information
Modified date: