IBM Support

Fix list for Informix Server 15.0.1.11 Release

Release Notes


Abstract

Informix Server provides periodic fixes for release 15.0. The following list is the most recent report of defect fixes for customer-reported defects in 15.0.1.11 release. This report combines both Windows and UNIX-specific defect fixes, and is more current than the defect information included in the product release.

Content

Fix Pack 15.0.1.11
Fix release date: 25 Jul 2026
Download: IBM Fix Central

KI IDKnown Issue Title
DT461067The CDR replay position won't advance while running an update on the source table which is not fully synced with target table.
DT467376The cdr sync command fails with '-1215: Value exceeds limit of INTEGER precision' after values in replcheck_stat_tab or replcheck_stat_node exceed 2147483647.
DT467723The dbinfo() routine returns incorrect results when attempting to determine the Informix version.
DT468409Creating or rebuilding an index generates a data distribution, but because partial indexes omit certain values, an UPDATE STATISTICS HIGH or MEDIUM command is required to ensure the distribution includes all available column data.
DT468416Partial index has a risk to be taken even when it should be clear that there will be no results.
DT243458IT44696: APPROXIMATELY 109 ERROR MESSAGE DESCRIPTIONS ARE MISSING FROM THE FINDERR TOOL
DT468006Memory corruption can occur while selecting from some sysmaster tables, resulting in assertion failures with varying stack traces.
DT468918Certain merge statements cause a persistent error -26918, after running for a certain number of iterations.
DT469504Recreation of an index on a table with table_size small can lead to corruption of that index.
DT471461Error 408 returned when a SELECT statement is issued from an old client includes the rowid even if the server is in compatibility mode.
DT470376Loading data into a fragmented table using an external table in EXPRESS mode with PDQPRIORITY 10 causes an Assert Fail.
DT470269Error 768 occurred in wrtminibin() routine when running UPDATE STATISTICS on a temp table using a non-DBSA user with Connect/Resource privileges after in-place upgrade.
DT470053The optimizer is choosing a less efficient plan when the query filter includes datetime year to fraction.

 

[{"Type":"MASTER","Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSGU8G","label":"Informix Servers"},"ARM Category":[{"code":"a8m500000008cqlAAA","label":"Informix Publications"}],"Platform":[{"code":"PF002","label":"AIX"},{"code":"PF016","label":"Linux"},{"code":"PF033","label":"Windows"},{"code":"PF035","label":"z\/OS"}],"Version":"15.0.1"}]