Error description
The application cloning DDL generator does not generate the COMPRESS keyword in the CREATE TABLE statements for tables that satisfy the following criteria: 1. Table resides in an implicit table space. 2. At some point, new columns were added to the source table with an ALTER ADD COLUMN.
Local fix
Manually create the affected table with the required attributes.
Problem summary
**************************************************************** * USERS AFFECTED: Users of Db2 Cloning Tool for z/OS. * **************************************************************** * PROBLEM DESCRIPTION: The application cloning DDL generator * * does not generate the COMPRESS keyword * * in the CREATE TABLE statements for * * tables that satisfy the following * * criteria: * * 1. Table resides in an implicit table * * space. * * 2. At some point, new columns were * * added to the source table with an ALTER * * ADD COLUMN. * **************************************************************** * RECOMMENDATION: Apply the PTF. * **************************************************************** The application cloning DDL generator does not generate the COMPRESS keyword in the CREATE TABLE statements for tables that satisfy the following criteria: 1. Table resides in an implicit table space. 2. At some point, new columns were added to the source table with an ALTER ADD COLUMN.
Problem conclusion
Apply the PTF.
Temporary fix
Comments
APAR Information
APAR number
PH71587
Reported component name
DB2 CLONING TOO
Reported component ID
5655N1000
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2026-06-02
Closed date
2026-06-24
Last modified date
2026-07-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
CKZ00110 CKZ00111 CKZ00112 CKZ00113 CKZ00117 CKZFGNTB CKZHACAI CKZHACAU CKZHACAW
Fix information
Fixed component name
DB2 CLONING TOO
Fixed component ID
5655N1000
Applicable component levels
R320 PSY UO08380
UP26/06/27 P F606
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2.0","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
02 July 2026