IBM Support

PH71206: HALOAD JOB CANCELED BY THE HEALTH MONITOR COMPLETES WITH RC=4 INSTEAD OF THE EXPECTED RC=8.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The HALOAD job is canceled by the health monitor when no load
    activity is detected within the configured timeout period.
    Although the job encounters a load timeout condition due to no
    load activity detected and ACCEL_LOAD_TABLES is canceled, the
    job incorrectly completes with a return code RC=4 instead of the
    expected RC=8.
    
    When this issue occurs, the job issues messages indicating
    inactivity timeout, cancellation of the ACCEL_LOAD_TABLES stored
    procedure, abnormal termination, and rollback of accelerator
    table changes. Query acceleration is also disabled for the
    affected accelerator tables. However, despite these error
    conditions, the job ends with RC=4 rather than signaling failure
    with RC=8.
    
    Job generates the following messages and ends with RC=4:
    
    HLOU5931I No load activity detected. Timeout expired seconds.
    Timeout remaining 0 seconds
    HLOU5935E ACCEL_LOAD_TABLES on accelerator canceled by .........
    Reason code 3
    HLOU5738I ACCEL_LOAD_TABLES stored procedure ended on , RC=0007
    HLOU5720I DSNT408I SQLCODE = -430, ERROR: PROCEDURE
    SYSPROC.ACCEL_LOAD_TABLES (SPECIFIC
    
    HLOU5720I NAME SYSPROC.ACCEL_LOAD_TABLES) HAS ABNORMALLY
    TERMINATED
    
    HLOU5720I DSNT418I SQLSTATE = 38503 SQLSTATE RETURN CODE
    
    HLOU5929E ACCEL_LOAD_TABLES was terminated due error or
    inactivity. Accelerator table changes are ROLLED BACK.
    
    HLOU4024W Disabling query acceleration for tables loaded on
    accelerator .
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Users                                    *
    ****************************************************************
    HALOAD job canceled by the health monitor completes with
    RC=4 instead of the expected RC=8.
    

Problem conclusion

  • HALOAD job canceled by the health monitor completes with
    RC=4 instead of the expected RC=8.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH71206

  • Reported component name

    IDAA LOADER ZOS

  • Reported component ID

    5639OLA00

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2026-05-06

  • Closed date

    2026-06-18

  • Last modified date

    2026-06-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • HLO#VERS HLO#WRIT HLOCLBK1 HLOCLBK2 HLOMSGEN HLOPIPE  HLOPIPEA
    HLOPIPEG HLOPOSRV HLOPSTPR HLORBKU1 HLORDELD HLORERD  HLORUSQL
    HLOSINIT HLOSTCMD HLOSUSQL HLOUBKU1 HLOUCBAS HLOUCE15 HLOUDELD
    HLOUGACG HLOUHAL1 HLOUHLTP HLOUHMON HLOUHTMG HLOUMAIN HLOUNTOK
    HLOUSE35 HLOUTMGR HLOUUMON
    

Fix information

  • Fixed component name

    IDAA LOADER ZOS

  • Fixed component ID

    5639OLA00

Applicable component levels

  • R310 PSY UO08311

       UP26/06/20 I 1000

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
20 June 2026