IBM Support

PH70407: ROLL UP PTF OF MULTIPLE INTERNAL FIXES FOR DSNACCOX EXCEPTIONS

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • This Roll Up PTF fixes the following Internal Issues with
    Exceptions dealing with DSNACCOX:
    1) DSNACCOX - Runstats utility - Exceptions are not
       triggering objects as expected
    2) DSNACCOX - DAJ498E - The specified value, coupled with the
                  comparison type being used, will always be
                  computed to unconditionally false.
    
    This error message will be displayed when the user enters a
    value in the exception condition field that is the maximum
    value for the column type that underlies the field.  This
    occurs, for example, when the comparison is a "GT" (greater
    than) operator, the underlying number type is a SMALLINT,
    and the entered value is 32767.  Although 32767 could be true
    with the GE operator, with GT - the condition could never
    compute to true.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Users                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: This Roll Up PTF fixes the following    *
    *                      Internal Issues with Exceptions dealing *
    *                      with DSNACCOX:                          *
    *                                                              *
    *                      1) DSNACCOX - RUNSTATS utility -        *
    *                      Exceptions are not triggering objects   *
    *                      as expected                             *
    *                      2) DSNACCOX - New Error Message         *
    *                      DAJ498E:                                *
    *                                                              *
    *                        DAJ498E - The specified value,        *
    *                        coupled with the comparison type      *
    *                        being used, will always be computed   *
    *                        to unconditionally false.             *
    *                                                              *
    *                      This error message will be displayed    *
    *                      when the user enters a value in the     *
    *                      exception condition field that is the   *
    *                      maximum value for the column type that  *
    *                      underlies the field.  This occurs, for  *
    *                      example, when the comparison is a "GT"  *
    *                      (greater than) operator, the underlying *
    *                      number type is a SMALLINT, and the      *
    *                      entered value is 32767.  Although 32767 *
    *                      could be true with the GE operator,     *
    *                      with GT - the condition could never     *
    *                      compute to true.                        *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF                                *
    ****************************************************************
    .
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PH70407

  • Reported component name

    AUTOMATION EXPE

  • Reported component ID

    5698DAE00

  • Reported release

    110

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2026-03-05

  • Closed date

    2026-04-21

  • Last modified date

    2026-05-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UO07551

Modules/Macros

  • DAJ#EPRI DAJ#ERTI DAJ$EPRU DAJ$ETRG DAJ$EXCP DAJ49    DAJ498E
    

Fix information

  • Fixed component name

    AUTOMATION EXPE

  • Fixed component ID

    5698DAE00

Applicable component levels

  • R110 PSY UO07551

       UP26/04/23 P F604

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.