Error description

  • Task history will incorrectly filter out tasks when the
    threshold for CPU is greater than 0.1 seconds.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IBM Z OMEGAMON AI for CICS users.        *
    ****************************************************************
    * PROBLEM DESCRIPTION: Task History filtering fails to return  *
    *                      transactions when a filter of greater   *
    *                      than 0.1 CPU seconds is used.           *
    *                      Task History will time out if more than *
    *                      100 records are retrieved on a single   *
    *                      request.                                *
    *                      Navigation from Context displays does   *
    *                      not align with requests from the        *
    *                      CICSplex view.                          *
    *                      The response time for viewing           *
    *                      Application Trace in the Enhanced       *
    *                      3270UI can be excessive.                *
    *                      The Enhanced 3270UI workspace KCPEXGD   *
    *                      may contain no data for a CICS region   *
    *                      where GLUEs are defined.                *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF.                              *
    ****************************************************************
    With IBM Z OMEGAMON AI 6.1 the format of the CPU value stored
    internally was changed. This resulted in the check for CPU
    values of greater than 0.1 seconds being misaligned.
    When more than 100 Task history rows are requested, multiple
    requests are made to task history. the timeout mechanism
    presumes the second query had timed out and results in it never
    being posted complete.
    The navigation options for the context displays are not similar
    to those of the CICSplex views.
    The processing of Application Trace data in the Enhanced 3270UI
    can take a long time.
    If the GLUEs defined for a CICS region are associated with a
    program which is not defined to CICS, no data is returned.
    

Problem conclusion

  • The comparison of the CPU time is now corrected.
    OMEGAMON is changed to correctly process subsequent task history
    requests.
    The navigation options for the CONTEXT displays have been
    updated to more closely match those of the CICSplex displays,
    this more consistent navigation is easier to use.
    The processing of Application Trace data in the Enhanced 3270UI
    has been redesigned to be significantly more efficient.
    OMEGAMON will now return data for GLUEs which are defined
    regardless of whether the program is known to CICS.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA69258

  • Reported component name

    OMEG XE CICS Z/

  • Reported component ID

    5698A5800

  • Reported release

    610

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / New Function / Xsystem

  • Submitted date

    2026-03-27

  • Closed date

    2026-04-01

  • Last modified date

    2026-05-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • KC5CTH00 KCPCNTEX KCPCNTXT KCPCONTX KCPD2P   KCPDISS  KCPDLP
    KCPENQP  KCPICP   KCPMIGRT KCPMQMP  KCPNAV1I KCPNAV2I KCPNAVCI
    KCPPRPL  KCPPSLAT KCPPSLR  KCPRLSC  KCPRZCMQ KCPRZINT KCPRZTRC
    KCPSTGO  KCPSTRTC KCPSTRTI KCPSTRTL KCPTASTR KCPTMIG1 KCPTMIG2
    KCPTMIG3 KCPTRACE KOCCDIG0 KOCCENG0 KOCCMG00 KOCNCC00 KOCOMM00
    KOCPC001 KOCSR2B0 KOCSR2C0 KOCSR2D0 KOCSR2E0 KOCSR2F0 KOCSR2G0
    KOCTRAB0 KOCTRAC0 KOCTRAD0 KOCTRAE0 KOCTRAF0 KOCTRAG0
    

Fix information

  • Fixed component name

    OMEG XE CICS Z/

  • Fixed component ID

    5698A5800

Applicable component levels

  • R610 PSY UJ99337

       UP26/04/02 P F604  