Appliance patch p135 causes Amazon Kinesis Data Streams capture failure.

Flashes (Alerts)


Abstract

Upgrading to appliance patch p135 may cause instability in capturing Datastream AWS activity. Customers who are on p125 and earlier are not affected.

Content

A disruption in capturing AWS activity via Datastream may occur when upgrading to patch p135 on v12.1 environments. This event occurs only with Datastream activity and is related to a certificate synchronization issue between the two storage mechanisms (PEM files and keystore). 

This issue does not impact customers running patch p125 or earlier.


 Remediation

Resolution:
The fix for this issue is included in the following patch:

  • SqlGuard-12.0p1027.tgz.enc.sig (see release notes)
  • Future appliance bundles starting Q1 2026.  

[{"Type":"MASTER","Line of Business":{"code":"LOB76","label":"Data Platform"},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSMPHH","label":"IBM Security Guardium"},"ARM Category":[{"code":"a8m0z000000Gp0JAAS","label":"APPLIANCE"}],"ARM Case Number":"","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"12.1.0"}]