A fix is available
APAR status
Closed as program error.
Error description
The IGNORING and INDICATING keywords in-context are missing from the sample alternate reserved word table IGY8CICS
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 6.4 who have used * * the IGY8CICS alternate reserved word table * * to compile COBOL programs containing the * * reserved-in-context keywords IGNORING or * * INDICATING (on the JSON GENERATE or JSON * * PARSE statements). * **************************************************************** * PROBLEM DESCRIPTION: When compiling a COBOL program that * * contains either the IGNORING or * * INDICATING keywords using the IGY8CICS * * alternate reserved word table, the * * compiler may issue this error message * * (or a similar one): * * * * IGYPS2072-S "IGNORING" was invalid. * * Skipped to the next verb, period or * * procedure-name definition. * **************************************************************** * RECOMMENDATION: Apply the provided PTF * **************************************************************** The IGNORING and INDICATING keywords were missing from the IGY8CICS alternate reserved word table shipped in the compiler SIGYSAMP dataset.
Problem conclusion
The IGNORING and INDICATING keyword definitions were added to the IGY8CICS alternate reserved word table. If users are encountering the problem above, they should apply the PTF and re-assemble and bind the new alternate reserved word table.
Temporary fix
Comments
APAR Information
APAR number
PH69381
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
640
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2025-12-12
Closed date
2025-12-12
Last modified date
2026-01-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UO06213 UO06214 UO06215
Modules/Macros
IGY8CICS IGY8RWRD IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCJGEN IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOPI IGYCOPT IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R640 PSY UO06213
UP25/12/18 P F512
R641 PSY UO06214
UP25/12/18 P F512
R642 PSY UO06215
UP25/12/18 P F512
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"640","Line of Business":{"code":"LOB70","label":"Z TPS"}}]
Document Information
Modified date: