IBM Support

Fix Pack 7.1.0.37 for Netcool/Impact adversely affects Insert Only Omnibus Event Readers

Flashes (Alerts)


Abstract

In Fix Pack 7.1.0.37, the method used to retrieve events in Omnibus Event Reader was changed to IDUC, replacing the Serial-based SQL Select statements. However, this change to IDUC, may adversely affect some setups.

Content

When Get updated events is not selected for an Omnibus Event Reader, the Reader reads inserted events only - not updated events. With Fix Pack 7.1.0.37 a change was made to use IDUC for these Insert-Only readers, instead of relying on Serial based Select statements. This change was introduced as part of DT442123.

However, the switch to IDUC, may adversely affect some setups, as follows:

Note:
With the switch to IDUC, Omnibus Events are required to have the FirstOccurrence field set.

For more information, refer to the following page:
Configuring the OMNIbusEventReader with an ObjectServer pair for New Events/Inserts

[{"Type":"MASTER","Line of Business":{"code":"LOB77","label":"Automation Platform"},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSSHYH","label":"Tivoli Netcool\/Impact"},"ARM Category":[{"code":"a8m500000008ZvtAAE","label":"Impact-\u003EImpact Server-\u003EOMNIbusEventReader"}],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1.0"}]

Document Information

Modified date:
08 December 2025

UID

ibm17253854