A fix is available
APAR status
Closed as program error.
Error description
The customer added some new functionality to an XICEREQ exit to ensure that certain EXEC CICS START requests are bypassed. After deploying the amended exit they encountered an abend0C4 at x'1EF4' in DFHPGCH. This is due to register 4, which should contain a pointer to the CHCB_EYECATCHER, being corrupt.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICS Users. * **************************************************************** * PROBLEM DESCRIPTION: ABEND0C4 in DFHPGCH when a CICS * * XICEREQ GLUE sets UERCBYP to bypass * * an EXEC CICS START TRANSID command. * **************************************************************** An application program issues EXEC CICS START TRANSID() and has an XICEREQ Global User Exit (GLUE) active. If the XICEREQ GLUE returns a return code of UERCBYP to CICS, requesting that the command should be bypassed then CICS can incorrectly call DFHPGCH with an invalid Channel_Token, leading to the 0C4 abend. The invalid channel token value was the result of residual TCA data from a previous BMS command. Additional Keywords: FFFFFFFF FFFFFFFE TCZICITK BMS
Problem conclusion
CICS has been changed to prevent an 0C4 in DFHPGCH when an XICEREQ GLUE returns UERCBYP.
Temporary fix
Comments
APAR Information
APAR number
PH69168
Reported component name
CICS TS Z/OS V6
Reported component ID
5655YA100
Reported release
400
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2025-11-26
Closed date
2026-02-25
Last modified date
2026-04-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UO06939 UO06940 UO06941
Modules/Macros
DFHEIIC
Fix information
Fixed component name
CICS TS Z/OS V6
Fixed component ID
5655YA100
Applicable component levels
R400 PSY UO06941
UP26/02/26 P F602
R500 PSY UO06940
UP26/03/06 P F603
R600 PSY UO06939
UP26/02/26 P F602
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.