A fix is available
APAR status
Closed as new function.
Error description
zCDP 1Q Continuous Delivery
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM Z Common Data Provider. * **************************************************************** * PROBLEM DESCRIPTION: This is a Continuous Delivery PTF with * * the updates listed in the Problem * * Summary. * **************************************************************** * RECOMMENDATION: APPLY this PTF and follow the ++HOLD. * **************************************************************** The following changes are provided in this PTF: - Node.js v22 upgrade; Config Tool updated to Angular v18 so it builds on Node.js v22 - SMF 119 record updates: added variables SMCD/SMCR (Subtype 11 and 12) - SMF 30, 230, and 119 (Subtype 2) - SMF 82 fields added for UKO Crypto Connect CAT - SMF 105 GDPS Global Mirror support - IMS record types support: X'CA01' and X'CA20'by Data Collector - SMF 121: added JCL Job section - CDP Data Collector support for new SMF records for native OpenTelemetry (OTEL) - MQ (SMF type 1158) - DB2 (SMF extended record type 1161, Subtype 1) - CICS (SMF type 1159) - IMS (SMF type 1160) - Both Data Streamer and Data Collector work with Kafka Cluster in HA mode with Multiple Kafka brokers - Kafka Data Compression - Both Data Streamer and Data Collector compress data before sending to Kafka using LZ4, GZIP, or zEDC (z/OS hardware-accelerated) compression, reducing network bandwidth and storage by 40-80% (Includes sample consumer applications for decompressing zEDC data on distributed platforms) - Proxy enhancements for Data Streamer: - SOCKS + certificate authorization to Splunk - HTTP + certificate authorization to Data Receiver Fixed Reported Problems: - From APAR OA68902 - Log Forwarder throwing Java Dump on refresh and TLS case - From APAR OA68923 - Splunk HEC with security subscriber - Sample SHBOSAMP(HBORACF) missing class name and missing connect of HBOLGF to group HBOGRP - Data Streamer gets HTTP error 400 connecting to Splunk - Data Streamer repeatedly logs "data sent to subscriber" - Sample SHBOSAMP(HBOMKWK) JCL has SOC4 ABEND - CDP COBOL API ABENDing with SOC4
Problem conclusion
Function was added and items were fixed.
Temporary fix
Comments
×**** PE26/03/10 FIX IN ERROR. SEE APAR OA69200 FOR DESCRIPTION
APAR Information
APAR number
OA68780
Reported component name
CDP BASE
Reported component ID
5698ABJ00
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / Xsystem
Submitted date
2025-11-17
Closed date
2026-02-26
Last modified date
2026-04-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ99070
Modules/Macros
HBO2CCMF HBO2CD53 HBO2CD54 HBO2CD55 HBO2CD56 HBO2CD61 HBO2CD62 HBO2CDIC HBO2CIST HBO2COMP HBO2S030 HBO2S042 HBO2S070 HBO2S078 HBO2S080 HBO2S082 HBO2S100 HBO2S101 HBO2S102 HBO2S104 HBO2S113 HBO2S30A HBO2S30O HBO2S42V HBO2S701 HBO2S702 HBO2TS77 HBO3CCMF HBO3CIST HBO3S701 HBOA2DUN HBOAILE HBOAIWLM HBOAKCUN HBOAKDUN HBOAKZUN HBOAPMUN HBOCBAPI HBOCBCLS HBOCBOPN HBOCBSND HBOCCORN HBOCCORY HBOCCSV HBOCDEDC HBOCDEDE HBOCDEDS HBOCDELF HBOCDEUI HBOCFGA HBOCFGT HBOCHGP HBOCMAIN HBOCMDTA HBOCSDTA HBODCBAT HBODCCOL HBODEPS HBODSDBG HBODSJOB HBODSPCE HBODSPRO HBODSRAW HBOFLGX0 HBOGDSDL HBOGLMSG HBOGTDBG HBOIMS HBOJBCO2 HBOJBCOL HBOJBDC2 HBOJBDCO HBOJBIM2 HBOJBIMS HBOJBLG2 HBOJBLGR HBOJCOLL HBOJIMS HBOLDCOL HBOLFBCH HBOLFPCE HBOLLREC HBOLLSMF HBOMDBG HBOMKFS HBOMKWK HBONETV HBOPASDI HBOPBLVL HBOPCDBI HBOPCGAA HBOPCGB1 HBOPCGB2 HBOPCGCM HBOPCGCW HBOPCGGC HBOPCGGF HBOPCGGP HBOPCGGX HBOPCGJA HBOPCGJC HBOPCGJE HBOPCGLO HBOPCGLW HBOPCGNN HBOPCGNO HBOPCGO1 HBOPCGO2 HBOPCGO3 HBOPCGO4 HBOPCGP1 HBOPCGP2 HBOPCGPA HBOPCGPC HBOPCGPF HBOPCGPN HBOPCGPP HBOPCGRC HBOPCGSF HBOPCGSM HBOPCGSW HBOPCGWD HBOPCGXC HBOPCGXF HBOPCGXI HBOPCGXS HBOPCGXT HBOPCGXV HBOPCGZA HBOPCGZC HBOPCGZG HBOPCGZM HBOPCGZP HBOPCGZS HBOPCGZZ HBOPCIBM HBOPCICP HBOPCMAA HBOPCMCR HBOPCMEV HBOPCMFP HBOPCMRN HBOPCMSC HBOPCMSP HBOPCMST HBOPCMSU HBOPCMSV HBOPCMZZ HBOPCOAS HBOPCOBF HBOPCOBI HBOPCOBU HBOPCOCF HBOPCOCR HBOPCOCS HBOPCODB HBOPCODI HBOPCOHA HBOPCOIT HBOPCOLL HBOPCOLX HBOPCOME HBOPCOMM HBOPCOMR HBOPCOOT HBOPCORE HBOPCORX HBOPCOSF HBOPCOST HBOPCOUR HBOPCOUT HBOPCPRE HBOPCSVD HBOPCXAA HBOPCXCA HBOPCXCC HBOPCXCT HBOPCXFC HBOPCXFI HBOPCXIC HBOPCXID HBOPCXLD HBOPCXLO HBOPCXNN HBOPCXNU HBOPCXO1 HBOPCXO2 HBOPCXO3 HBOPCXO4 HBOPCXPX HBOPCXSE HBOPCXUS HBOPCXVA HBOPCXVR HBOPDBRC HBOPDE HBOPDELO HBOPDERE HBOPDERP HBOPDETA HBOPDETP HBOPDEUP HBOPDICA HBOPDICC HBOPDICD HBOPDICF HBOPDICI HBOPDICR HBOPDICS HBOPEN36 HBOPFRFA HBOPFRFL HBOPFRFM HBOPFRFN HBOPFRFT HBOPFRLX HBOPFRSA HBOPFRSL HBOPFRSN HBOPFRSS HBOPIFAQ HBOPIMID HBOPIMS HBOPIMSD HBOPIMSN HBOPIO HBOPIO31 HBOPLIPR HBOPLLPR HBOPLODT HBOPLOEX HBOPLOG HBOPLOOI HBOPLOOK HBOPLOOU HBOPLOPE HBOPLOPF HBOPLOPR HBOPLOST HBOPLSMC HBOPLSPR HBOPMG HBOPMG00 HBOPMG01 HBOPMG02
Fix information
Fixed component name
CDP BASE
Fixed component ID
5698ABJ00
Applicable component levels
R510 PSY UJ99070
UP26/04/02 P F603
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.