Error description

  • This is an enhancement to support image copy of a DEDB database
    with > 2048 areas in one step.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS High Performance Image Copy for      *
    *                 z/OS Version 4.2 users ( FMID=H1J0420 )      *
    ****************************************************************
    * PROBLEM DESCRIPTION: IMS HP Image Copy supports more than    *
    *                      2048 DEDB areas in the image copy       *
    *                      function of FABJMAIN program. The Image *
    *                      Copy function executed by FABJMAIN      *
    *                      program supports DEDB area data sets    *
    *                      and DB data sets exceeding 2048.        *
    *                      For this support, the "AREA NUMBER"     *
    *                      field value in the Data Set Statistics  *
    *                      report for a DEDB changes to four       *
    *                      digits.                                 *
    *                      This APAR also fixes followings:        *
    *                      - Issue NOTIFY.IC command correctly     *
    *                        when FASTIC=(opt,COPY),               *
    *                        NOTIFYMODE=COND and DEDBPC=Y are      *
    *                        specified in ICEIN DD, and IMS HP     *
    *                        Image Copy creates primary image copy *
    *                        data set only                         *
    *                      - Avoid ABEND S0C4 ( ABEND0C4 ) caused  *
    *                        by Instruction Execution Protection   *
    *                        of OS macro                           *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR          *
    ****************************************************************
    IMS HP Image Copy supports more than 2048 DEDB areas in the
    image copy function of FABJMAIN program. The Image Copy function
    executed by FABJMAIN program supports DEDB area data sets and DB
    data sets exceeding 2048.
    
    The maximum number of ICEIN control statements that you can
    specify in one job step for the Image Copy function is still
    2048. If you plan to process more than 2048 data sets in the
    step, you should:
    - Specify DBD keywords without the AREA keyword or DDN keyword
    - For DEDB, use wildcard option or range option of AREA keyword
    For this support, the "AREA NUMBER" field value in the Data Set
    Statistics report for a DEDB changes to four digits.
    
    This APAR also fixes followings:
    - Issue NOTIFY.IC command correctly when FASTIC=(opt,COPY),
      NOTIFYMODE=COND and DEDBPC=Y are specified in ICEIN DD, and
      IMS HP Image Copy creates primary image copy data set only
    
      The NOTIFY.IC command is not performed because the internal
      control flag is not set properly. It has been fixed by
      properly managing the internal control flag to allow the
      NOTIFY.IC command to execute.
    
    - Avoid ABEND S0C4 ( ABEND0C4 ) caused by Instruction Execution
      Protection of OS macro
    
      The default value of the EXECUTABLE option of the STORAGE
      macro has been changed to NO from YES. IMS HP Image Copy uses
      the STORAGE macro without the EXECUTABLE option, which
      contains a potential issue that can cause ABEND S0C4.
      Therefore, the program has been modified to explicitly specify
      EXECUTABLE=YES for STORAGE within the program.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PH68426

  • Reported component name

    IMS HP IMAGE CO

  • Reported component ID

    5655K9600

  • Reported release

    420

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / New Function / Xsystem

  • Submitted date

    2025-10-07

  • Closed date

    2025-12-10

  • Last modified date

    2026-01-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UO06161

Modules/Macros

  • FABJCRC3 FABJDFC2 FABJDFC3 FABJDFC4 FABJDFC5 FABJDFC9 FABJDFCA
    FABJDFCB FABJDOPN FABJDPS2 FABJDPS3 FABJDPS4 FABJDPS5 FABJDPS9
    FABJDPSA FABJDPSB FABJICDD FABJISDD FABJMAIN FABJPARM FABJRPT1
    FABJXCR  FABJXHPC
    

Fix information

  • Fixed component name

    IMS HP IMAGE CO

  • Fixed component ID

    5655K9600

Applicable component levels

  • R420 PSY UO06161

       UP25/12/12 P F512  

Fix is available