A fix is available
APAR status
Closed as program error.
Error description
DFHRMUTL utility program does not provide output when it is run using ZOAU command 'mvscmd'. DFHRMUTL has successfully completed but fails to pass the SYSOUT to the command line and results in ZOAU error messages being issued instead.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICS users. * **************************************************************** * PROBLEM DESCRIPTION: DFHRMUTL utility program does not * * provide output when it is run using * * ZOAU command 'mvscmd'. DFHRMUTL has * * successfully completed but fails to * * pass the SYSOUT to the command line and * * results in ZOAU error messages being * * issued instead. * **************************************************************** DFHRMUTL utility program does not provide output when it is run using ZOAU command 'mvscmd'. DFHRMUTL has successfully completed but fails to pass the SYSOUT to the command line and ends with following ZOAU error messages: BGYSC0266E Error freeing DDName SYSIN from stdin. BGYSC0265E Error freeing DDName SYSPRINT from console. The SYSIN and SYSPRINT DCBs are not being closed in the program and this resulted in ZOAU to throw the error.
Problem conclusion
Code has been added to DFHRMUTL program to close the SYSIN and SYSPRINT DCBs before the termination of the program.
Temporary fix
Comments
APAR Information
APAR number
PH68286
Reported component name
CICS TS Z/OS V6
Reported component ID
5655YA100
Reported release
400
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2025-09-25
Closed date
2025-11-18
Last modified date
2025-11-30
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
PH68821 UO05836 UO05837
Modules/Macros
DFHRMUTL
Fix information
Fixed component name
CICS TS Z/OS V6
Fixed component ID
5655YA100
Applicable component levels
Fix is available