Error description
CICS PA List extract abends with code S002-18 when a timestamp field is specified without a format in the LIST FIELDS command. The fix is to set the Timestamp default format to TIMET.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All USERS OF CICS PA 5.4. * **************************************************************** * PROBLEM DESCRIPTION: CICS PA List extract abends with code * * S002-18 when a timestamp field is * * specified without a format in the LIST * * FIELDS command. * **************************************************************** CICS PA List extract abends with code S002-18 when a timestamp field is specified without a format in the LIST FIELDS command.
Problem conclusion
This APAR sets the timestamp field format to default TIMET when the format is not specified in the LIST FIELDS extract command.
Temporary fix
Comments
APAR Information
APAR number
PH67850
Reported component name
CICS PERF ANALY
Reported component ID
5655Y2300
Reported release
540
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2025-08-21
Closed date
2025-10-06
Last modified date
2025-11-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UO05222
Modules/Macros
CPALSTMF
Fix information
Fixed component name
CICS PERF ANALY
Fixed component ID
5655Y2300
Applicable component levels
R540 PSY UO05222
UP25/10/09 P F510
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSPPU4","label":"CICS Performance Analyzer for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.4","Line of Business":{"code":"LOB70","label":"Z TPS"}}]