PH67319: CATALOG MANAGER SUPPORTS IMS MODIFICATIONS PROVIDED BY IMS APAR PH18953 AND PH62176

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When IMS APAR PH18953 is not applied and DEDB has FPSI defined
    and specifying a SRCH field to use part of the concatenated key,
    the /CK information does not stored in the IMS catalog database.
    After applying IMS APAR PH18953, it is stored to new field in
    the IMS catalog database however the Catalog Manager does not
    retrieve it from new field.
    IMS APAR PH62176 fixes incorrect SCAN= value of DATASET
    statement in DBDs in the IMS catalog database. The decode
    function of the Catalog Manager does not decodes the stored
    value when SCAN=0 is specified.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: IMS Library Integrity Utilities (LIU) for    *
    *                 z/OS, Version 2 Release 2 (FMID=H27P220)     *
    *                 users who use the Catalog Manager utility    *
    *                 or LIU under the IMS Administration Tool.    *
    ****************************************************************
    * PROBLEM DESCRIPTION: When IMS APAR PH18953 is applied, /CK   *
    *                      information for DEDB which has FPSI is  *
    *                      stored correctly to the new field in    *
    *                      the IMS catalog database. Library       *
    *                      Integrity utilities (LIU) should        *
    *                      retrieve the /CK information from new   *
    *                      field. Also, LIU should decode DATASET  *
    *                      SCAN parameter for HIDAM or HDAM even   *
    *                      when SCAN=0 is stored in the IMS        *
    *                      catalog database.                       *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    When IMS APAR PH18953 is not applied and DEDB has FPSI defined
    and specifying a SRCH field to use part of the concatenated
    key, the /CK information is not stored in the IMS catalog
    database correctly. After applying IMS APAR PH18953, the
    correct value is stored to the new field in the IMS catalog
    database however the Library Integrity Utilities (LIU) does not
    retrieve it from the new field. This APAR fixes the LIU to
    retrieve the /CK information from new field in the IMS catalog
    database.
    The map function of the Catalog Manager can report these value
    correctly and LIU under the IMS Administration Tool can decode
    DBD source with these correct value.
    
    This APAR also fixes LIU to decode SCAN=0 in DATASET
    statement for HIDAM or HDAM even when SCAN=0 is stored in the
    IMS catalog database. Without IMS APAR PH62176, SCAN=0 value
    is not stored in the IMS catalog database. After applying IMS
    APAR PH62176, SCAN=0 is stored however LIU does not decode it.
    This APAR fixes the Catalog Manager and LIU under the IMS
    Administration Tool to decode SCAN value even when the value
    is 0.
    

Problem conclusion

  • The following modules and macro have been changed to fix the
    problem:
    FABXCDDD, FABXCMRD, FABXDST0
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH67319

  • Reported component name

    IMS LIBR INTEG

  • Reported component ID

    5655I4200

  • Reported release

    220

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2025-07-14

  • Closed date

    2025-07-31

  • Last modified date

    2025-08-31

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UO04342

Modules/Macros

  • FABXCDDD FABXCMRD
    

Fix information

  • Fixed component name

    IMS LIBR INTEG

  • Fixed component ID

    5655I4200

Applicable component levels

  • R220 PSY UO04342

       UP25/08/02 P F508

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89N","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220"}]

Document Information

Modified date: