A fix is available
APAR status
Closed as program error.
Error description
The size of the root addressable area (RAA) for PHDAM can be smaller than expected after running MAINTAIN.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM IMS HALDB Toolkit 1.1. * **************************************************************** * PROBLEM DESCRIPTION: The size of the root addressable area * * (RAA) for PHDAM can be smaller than * * expected after running MAINTAIN. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** The maximum relative block number in the RECON data set is not inherited and the maximum relative block number after repartitioning was calculated based on the rbn of the DBD. Under this condition, the size of the root addressable area can be smaller than expected after running MAINTAIN. In addition, the following fix has been applied in this APAR. - When running MAINTAIN with ONLINE(Y), only some partitions are processed and partition selection exit DFSPSE00 is defined in RECON, MAINTAIN can get TRERR IHCYPS15 0999 because all partitions are not defined in a temporary RECON.
Problem conclusion
- Code has been changed to inherite the maximum relative block number in the RECON data set after running MAINTAIN. - Code has been changed to define all partitions in a temporary RECON when running MAINTAIN with ONLINE(Y) even if only some partitions are processed.
Temporary fix
Comments
APAR Information
APAR number
PH67194
Reported component name
IMS HALDB TOOLK
Reported component ID
5655DBU01
Reported release
110
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2025-07-03
Closed date
2025-07-29
Last modified date
2025-08-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UO04288
Modules/Macros
IHCULEV0 IHCWTDB1 IHCWTDB4
Fix information
Fixed component name
IMS HALDB TOOLK
Fixed component ID
5655DBU01
Applicable component levels
R110 PSY UO04288
UP25/07/31 P F507
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCBQAP","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.1.0"}]
Document Information
Modified date: