Error description
When running a Unit Test, with a recording made against a program that has a large data structure, code coverage reports are not properly generated. The issue occurs with the FILLER area of the uninitialized data structure during a replay does not match the same area in the original recording. It appears that changing the elementary FILLER data item to a non-FILLER name allows code coverage to run properly. However, that is just coincidence as there is no compiler differences based on name. The solution is to provide the Language Environment (LE) option STORAGE, to initialize the data structure.
Local fix
Problem summary
When running a Unit Test, with a recording made against a program that has a large data structure, code coverage reports are not properly generated. The issue occurs with the FILLER area of the uninitialized data structure during a replay does not match the same area in the original recording. It appears that changing the elementary FILLER data item to a non-FILLER name allows code coverage to run properly. However, that is just coincidence as there is no compiler differences based on name. The solution is to provide the Language Environment (LE) option STORAGE, to initialize the data structure.
Problem conclusion
Fixed in TAZ 1.0.4 and 2.0.0
Temporary fix
Comments
APAR Information
APAR number
PH67097
Reported component name
TEST ACCELERATO
Reported component ID
5900BBG00
Reported release
100
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2025-06-25
Closed date
2025-09-23
Last modified date
2025-09-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TEST ACCELERATO
Fixed component ID
5900BBG00
Applicable component levels
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSLGKGY","label":"IBM Test Accelerator for Z"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"100","Line of Business":{"code":"LOB70","label":"Z TPS"}}]
Document Information
Modified date:
24 September 2025