APAR status
Closed as program error.
Error description
"mmhealth cluster show" my report an additional GUI pod after upgrade or rebalancing.
Local fix
Moving the cluster manager node (mmchmgr) will ensure a resync of the data. "mmhealth node show -a --resend" will do the same
Problem summary
"mmhealth cluster show" my report an additional GUI pod after upgrade or rebalancing.
Problem conclusion
This problem is fixed in 5.2.3.1 To see all Spectrum Scale APARs and their respective Fix solutions refer to page: https://public.dhe.ibm.com/storage/spectrumscale/spectrum_scale _apars.html Benefits of the solution: Fixed race condition and messaging will ensure correct status display with "mmhealth cluster show" Work Around: Moving the cluster manager node (mmchmgr) will ensure a resync of the data. "mmhealth node show -a --resend" will do the same Problem trigger: CNSA Upgrade or other rebalancing action of GUI pods. Symptom: Unexpected Results/Behavior Platforms affected: Open Shift (CNSA) Functional Area affected: System Health Customer Impact: Suggested
Temporary fix
Comments
APAR Information
APAR number
IJ54975
Reported component name
SPEC SCALE STD
Reported component ID
5737F33AP
Reported release
523
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2025-06-04
Closed date
2025-06-24
Last modified date
2025-06-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SPEC SCALE STD
Fixed component ID
5737F33AP
Applicable component levels
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"STXKQY"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"523","Line of Business":{"code":"LOB69","label":"Storage TPS"}}]
Document Information
Modified date:
24 June 2025