IBM Support

IBM i Removable Media: Power11 tape and optical

News


Abstract

This document provided details for the tape and optical devices that are supported on Power11 systems by IBM i.

Content

Supported server models

  • IBM Power E1180 (9080-HEU)
  • IBM Power S1122 (9824-22A)
  • IBM Power S1124 (9824-42A)
  • IBM Power L1122 (9856-22H)
  • IBM Power L1124 (9856-42H)
Supported releases for S1122 (with processor feature code #ERGR), E1180, and S1124
  • IBM i 7.4 TR12
  • IBM i 7.5 TR6 or later
  • IBM i 7.6 Power11 GA PTF Group
  • IBM i 7.6 TR1
  • IBM VIOS 3.1.4.41 with client IBM i 7.4 TR12, IBM i 7.5 (TR6 or later), IBM i 7.6 with the Power11 GA PTF group, or IBM i 7.6 TR1
  • IBM VIOS 3.1.4.50 with client IBM i 7.4 TR12, IBM i 7.5 (TR6 or later), IBM i 7.6 with the Power11 GA PTF group, or IBM i 7.6 TR1
  • IBM VIOS 4.1.0.21 with client IBM i 7.4 TR12, IBM i 7.5 (TR6 or later), IBM i 7.6 with the Power11 GA PTF group, or IBM i 7.6 TR1
  • IBM VIOS 4.1.1 with client IBM i 7.4 TR12, IBM i 7.5 (TR6 or later), IBM i 7.6 with the Power11 GA PTF group, or IBM i 7.6 TR1
  • IBM VIOS 4.1.2 with client IBM i 7.4 TR12, IBM i 7.5 (TR6 or later), IBM i 7.6 with the Power11 GA PTF group, or IBM i 7.6 TR1
Supported releases for S1122 (with processor feature codes #ERG0,#EBG8,#EBG9,#EBGA), L1122, and L1124
  • IBM VIOS 3.1.4.41 with client IBM i 7.4 TR12, IBM i 7.5 (TR6 or later), IBM i 7.6 with the Power11 GA PTF group, or IBM i 7.6 TR1
  • IBM VIOS 3.1.4.50 with client IBM i 7.4 TR12, IBM i 7.5 (TR6 or later), IBM i 7.6 with the Power11 GA PTF group, or IBM i 7.6 TR1
  • IBM VIOS 4.1.0.21 with client IBM i 7.4 TR12, IBM i 7.5 (TR6 or later), IBM i 7.6 with the Power11 GA PTF group, or IBM i 7.6 TR1
  • IBM VIOS 4.1.1 with client IBM i 7.4 TR12, IBM i 7.5 (TR6 or later), IBM i 7.6 with the Power11 GA PTF group, or IBM i 7.6 TR1
  • IBM VIOS 4.1.2 with client IBM i 7.4 TR12, IBM i 7.5 (TR6 or later), IBM i 7.6 with the Power11 GA PTF group, or IBM i 7.6 TR1

Supported adapters and devices     

    Note: No internal removable media devices are supported by IBM i on Power11.

    Note: VIOS does not support SAS tape library devices, but a TS2900 SAS tape library device that is configured to operate in Sequential mode can be attached to a VIOS partition.

    Note:  When a Fibre Channel tape device is attached by using a VIOS partition (NPIV support) a SAN switch is always required.

SAS adapters:

  • FC EJ2B (CCIN 57F2) 12 Gb 4-port SAS.  (Native only, not supported by VIOS) Supported on server models: 9080-HEU, *9824-22A, 9824-42A  (*  - 9824-22A requires processor feature #ERGR and the EEPS VET code for Native I/O support)
    • TS2250 LTO-5 SAS HH stand-alone tape drive
    • TS2350 LTO-5 SAS FH stand-alone tape drive
    • TS2260 LTO-6 SAS HH stand-alone tape drive
    • TS2360 LTO-6 SAS FH stand-alone tape drive
    • TS2270 LTO-7 SAS HH stand-alone tape drive
    • TS2280 LTO-8 SAS HH stand-alone tape drive
    • TS2290 LTO-9 SAS HH stand-alone tape drive
    • HH LTO-5 SAS, 7226 with FC8241
    • HH LTO-6 SAS, 7226 with FC8341
    • HH LTO-7 SAS, 7226 with FC8441
    • HH LTO-8 SAS, 7226 with FC8541
    • HH LTO-9 SAS, 7226 with FC8641
    • 3555 (TS4300) with SAS LTO6, LTO7, LTO8, or LTO9 drives
    • 3572 (TS2900) with SAS LTO5, LTO6, LTO7, LTO8, or LTO9 drives
    • 3573 (TS3100, TS3200) with SAS LTO5, LTO6, LTO7, or LTO8 drives
    • Diamondback tape library with SAS LTO9 or LTO10 drives.
  • FC EJ2C (CCIN 57F2) 12 Gb 4-port SAS low profile.  (Native only, not supported by VIOS) Supported on server models: 9080-HEU, *9824-22A (* - 9824-22A requires processor feature #ERGR and the EEPS VET code for Native I/O support)
    • TS2250 LTO-5 SAS HH stand-alone tape drive
    • TS2350 LTO-5 SAS FH stand-alone tape drive
    • TS2260 LTO-6 SAS HH stand-alone tape drive
    • TS2360 LTO-6 SAS FH stand-alone tape drive
    • TS2270 LTO-7 SAS HH stand-alone tape drive
    • TS2280 LTO-8 SAS HH stand-alone tape drive
    • TS2290 LTO-9 SAS HH stand-alone tape drive
    • HH LTO-5 SAS, 7226 with FC8241
    • HH LTO-6 SAS, 7226 with FC8341
    • HH LTO-7 SAS, 7226 with FC8441
    • HH LTO-8 SAS, 7226 with FC8541
    • HH LTO-9 SAS, 7226 with FC8641
    • 3555 (TS4300) with SAS LTO-6, LTO-7, LTO-8, or LTO-9 drives
    • 3572 (TS2900) with SAS LTO-5, LTO-6, LTO-7, LTO-8, or LTO-9 drives
    • 3573 (TS3100, TS3200) with SAS LTO-5, LTO-6, LTO-7, or LTO-8 drives
    • Diamondback tape library with SAS LTO9 or LTO10 drives.    
Fibre Channel adapters:
  • FC EN1A (CCIN 578F) 32 Gb 2-port Fibre Channel (Native or NPIV VIOS support) (This adapter does not support direct attach to tape except for natively attached full height LTO10 drives) Supported on server models: 9080-HEU, 9824-22A, 9824-42A, 9856-22H, 9856-42H.
    • 3555/5544 (TS4300) with Fibre Channel LTO6, LTO7, LTO8, LTO9, or LTO10 drives
    • 3573 (TS3100, TS3200) with Fibre Channel LTO5, LTO6, LTO7, or LTO8 drives
    • 3576 (TS3310) with Fibre Channel LTO5, LTO6, LTO7, or LTO8 drives
    • 3584 (TS3500) with Fibre Channel LTO5, LTO6, LTO7, or LTO8 drives
    • 3584 (TS3500) with Fibre Channel 3592-E08 (TS1150), 3592-55G (TS1155), or 3592-60G (TS1160) drives
    • 3584 (TS4500) with Fibre Channel LTO5, LTO6, LTO7, LTO8, LTO9, LTO10, 3592-EH8 (TS1150), 3592-55F (TS1155), 3592-60F (TS1160), or 3592-70F (TS1170) drives.
    • Diamondback tape library with Fibre Channel LTO9 or LTO10 drives.
    • 3592-E08 (TS1150), or 3592-70F (TS1170) rack-mount drives
    • FC 8248 HH-LTO5 FC in 7226 enclosure
    • FC 8348 HH-LTO6 FC in 7226 enclosure
    • FC 8446 HH-LTO7 FC in 7226 enclosure
    • FC 8546 HH-LTO8 FC in 7226 enclosure
    • FC 8646 HH LTO-9 Fibre Channel in 7226 enclosure
  • FC EN1B (CCIN 578F) 32 Gb 2-port low profile Fibre Channel (Native or NPIV VIOS support) (This adapter does not support direct attach to tape except for natively attached full height LTO10 drives) Supported on server models: 9080-HEU, 9824-22A,  9856-22H.
    • 3555/5544 (TS4300) with Fibre Channel LTO6, LTO7, LTO8, LTO9, or LTO10 drives
    • 3573 (TS3100, TS3200) with Fibre Channel LTO5, LTO6, LTO7, or LTO8 drives
    • 3576 (TS3310) with Fibre Channel LTO5, LTO6, LTO7, or LTO8 drives
    • 3584 (TS3500) with Fibre Channel LTO5, LTO6, LTO7, or LTO8 drives
    • 3584 (TS3500) with Fibre Channel 3592-E08 (TS1150), 3592-55G (TS1155), or 3592-60G (TS1160) drives
    • 3584 (TS4500) with Fibre Channel LTO5, LTO6, LTO7, LTO8, LTO9, LTO10, 3592-EH8 (TS1150), 3592-55F (TS1155), 3592-60F (TS1160), or 3592-70F (TS1170) drives.
    • Diamondback tape library with Fibre Channel LTO9 or LTO10 drives.
    • 3592-E08 (TS1150), or 3592-70F (TS1170) rack-mount drives
    • FC 8248 HH-LTO5 FC in 7226 enclosure
    • FC 8348 HH-LTO6 FC in 7226 enclosure
    • FC 8446 HH-LTO7 FC in 7226 enclosure
    • FC 8546 HH-LTO8 FC in 7226 enclosure
    • FC 8646 HH LTO-9 Fibre Channel in 7226 enclosure
  • FC EN1J (CCIN 579C) 32 Gb 2-port Fibre Channel (Native or NPIV VIOS support) Supported on server models: 9080-HEU, 9824-22A, 9824-42A, 9856-22H, 9856-42H. This native adapter can support direct attach to a tape device with an 8Gb Fibre Channel interface when the device port is configured to run using Fibre Channel Arbitrated Loop.   This adapter can also support direct attach to full height LTO10 tape drives.  The following devices are supported:
    • 3555/5544 (TS4300) with Fibre Channel LTO6, LTO7, LTO8, LTO9, or LTO10 drives.  For direct attach support, change the Port Type setting to Loop (L)
    • 3573 (TS3100, TS3200) with Fibre Channel LTO5, LTO6, LTO7, or LTO8 drives.  For direct attach support, change the Topology setting to L-port or LN-port
    • 3576 (TS3310) with Fibre Channel LTO5, LTO6, LTO7, or LTO8 drives.  For direct attach support, use Modify Port Properties to change the setting to L port
    • 3584 (TS3500) with Fibre Channel LTO5, LTO6, LTO7, or LTO8 drives.  For direct attach support, change the Set Link Speed/Topology setting to L Port
    • 3584 (TS3500) with Fibre Channel 3592-E08 (TS1150), 3592-55G (TS1155), or 3592-60G (TS1160) drives. For direct attach support for 3592-E08  and 3592-55G, change the Set Link Speed/Topology setting to L Port.  Direct attach to 3592-60G is not supported by FC EN1J
    • 3584 (TS4500) with Fibre Channel LTO5, LTO6, LTO7, LTO8, LTO9, LTO10, 3592-EH8 (TS1150), 3592-55F (TS1155), 3592-60F (TS1160), or 3592-70F (TS1170) drives.  Direct attach to 3592-60F and 3592-70F is not supported by FC EN1J.  For direct attach support with LTO5, LTO6, LTO7, LTO8, and LTO9 use Modify Topology... to change the port topology to L Port.
    • Diamondback tape library with Fibre Channel LTO9 or LTO10 drives.  For direct attach support with LTO9 drives use Modify Topology... to change the port topology to L Port.
    • 3592-E08 (TS1150) or 3592-70F (TS1170) rack-mount drives.  Direct attach to 3592-70F is not supported by FC EN1J.  The other devices are already configured to support direct attach
    • FC 8248 HH-LTO5 FC in 7226 enclosure.  This device is already configured to support direct attach
    • FC 8348 HH-LTO6 FC in 7226 enclosure.  This device is already configured to support direct attach
    • FC 8446 HH-LTO7 FC in 7226 enclosure.  This device is already configured to support direct attach
    • FC 8546 HH-LTO8 FC in 7226 enclosure.  This device is already configured to support direct attach
    • FC 8646 HH LTO-9 Fibre Channel in 7226 enclosure.  This device is already configured to support direct attach
  • FC EN1K (CCIN 579C) 32 Gb 2-port low profile Fibre Channel (Native or NPIV VIOS support) Supported on server models: 9080-HEU, 9824-22A, 9856-22H. This native adapter can support direct attach to a tape device with an 8Gb Fibre Channel interface when the device port is configured to run using Fibre Channel Arbitrated Loop.   This adapter can also support direct attach to full height LTO10 tape drives.  The following devices are supported:
    • 3555/5544 (TS4300) with Fibre Channel LTO6, LTO7, LTO8, LTO9, or LTO10 drives.  For direct attach support, change the Port Type setting to Loop (L)
    • 3573 (TS3100, TS3200) with Fibre Channel LTO5, LTO6, LTO7, or LTO8 drives.  For direct attach support, change the Topology setting to L-port or LN-port
    • 3576 (TS3310) with Fibre Channel LTO5, LTO6, LTO7, or LTO8 drives.  For direct attach support, use Modify Port Properties to change the setting to L port
    • 3584 (TS3500) with Fibre Channel LTO5, LTO6, LTO7, or LTO8 drives.  For direct attach support, change the Set Link Speed/Topology setting to L Port
    • 3584 (TS3500) with Fibre Channel 3592-E08 (TS1150), 3592-55G (TS1155), or 3592-60G (TS1160) drives. For direct attach support for 3592-E08  and 3592-55G, change the Set Link Speed/Topology setting to L Port.  Direct attach to 3592-60G is not supported by FC EN1J
    • 3584 (TS4500) with Fibre Channel LTO5, LTO6, LTO7, LTO8, LTO9, LTO10, 3592-EH8 (TS1150), 3592-55F (TS1155), 3592-60F (TS1160), or 3592-70F (TS1170) drives.  Direct attach to 3592-60F and 3592-70F is not supported by FC EN1J.  For direct attach support with LTO5, LTO6, LTO7, LTO8, and LTO9 use Modify Topology... to change the port topology to L Port.
    • Diamondback tape library with Fibre Channel LTO9 or LTO10 drives.  For direct attach support with LTO9 drives use Modify Topology... to change the port topology to L Port.
    • 3592-E08 (TS1150) or 3592-70F (TS1170) rack-mount drives.  Direct attach to 3592-70F is not supported by FC EN1J.  The other devices are already configured to support direct attach
    • FC 8248 HH-LTO5 FC in 7226 enclosure.  This device is already configured to support direct attach
    • FC 8348 HH-LTO6 FC in 7226 enclosure.  This device is already configured to support direct attach
    • FC 8446 HH-LTO7 FC in 7226 enclosure.  This device is already configured to support direct attach
    • FC 8546 HH-LTO8 FC in 7226 enclosure.  This device is already configured to support direct attach
    • FC 8646 HH LTO-9 Fibre Channel in 7226 enclosure.  This device is already configured to support direct attach
  • FC EN1L  (CCIN 2CFC) 32 Gb 4-port Fibre Channel (Native or NPIV VIOS support) This adapter does not support direct attach to tape except for natively attached full height LTO10 drives.  Supported on server models: 9080-HEU, 9824-22A, 9824-42A, 9856-22H, 9856-42H.
    • 3555/5544 (TS4300) with Fibre Channel LTO6, LTO7, LTO8, LTO9, or LTO10 drives
    • 3573 (TS3100, TS3200) with Fibre Channel LTO5, LTO6, LTO7, or LTO8 drives
    • 3576 (TS3310) with Fibre Channel LTO5, LTO6, LTO7, or LTO8 drives
    • 3584 (TS3500) with Fibre Channel LTO5, LTO6, LTO7, or LTO8 drives
    • 3584 (TS3500) with Fibre Channel 3592-E08 (TS1150), 3592-55G (TS1155), or 3592-60G (TS1160) drives
    • 3584 (TS4500) with Fibre Channel LTO5, LTO6, LTO7, LTO8, LTO9, LTO10, 3592-EH8 (TS1150), 3592-55F (TS1155), 3592-60F (TS1160), or 3592-70F (TS1170) drives.
    • Diamondback tape library with Fibre Channel LTO9 or LTO10 drives.
    • 3592-E08 (TS1150), or 3592-70F (TS1170) rack-mount drives
    • FC 8248 HH-LTO5 FC in 7226 enclosure
    • FC 8348 HH-LTO6 FC in 7226 enclosure
    • FC 8446 HH-LTO7 FC in 7226 enclosure
    • FC 8546 HH-LTO8 FC in 7226 enclosure
    • FC 8646 HH LTO-9 Fibre Channel in 7226 enclosure
  • FC EN1M  (CCIN 2CFC) 32 Gb LP 4-port Fibre Channel (Native or NPIV VIOS support) This adapter does not support direct attach to tape except for natively attached full height LTO10 drives.  Supported on server models: 9080-HEU
    • 3555/5544 (TS4300) with Fibre Channel LTO6, LTO7, LTO8, LTO9, or LTO10 drives
    • 3573 (TS3100, TS3200) with Fibre Channel LTO5, LTO6, LTO7, or LTO8 drives
    • 3576 (TS3310) with Fibre Channel LTO5, LTO6, LTO7, or LTO8 drives
    • 3584 (TS3500) with Fibre Channel LTO5, LTO6, LTO7, or LTO8 drives
    • 3584 (TS3500) with Fibre Channel 3592-E08 (TS1150), 3592-55G (TS1155), or 3592-60G (TS1160) drives
    • 3584 (TS4500) with Fibre Channel LTO5, LTO6, LTO7, LTO8, LTO9, LTO10, 3592-EH8 (TS1150), 3592-55F (TS1155), 3592-60F (TS1160), or 3592-70F (TS1170) drives.
    • Diamondback tape library with Fibre Channel LTO9 or LTO10 drives.
    • 3592-E08 (TS1150), or 3592-70F (TS1170) rack-mount drives
    • FC 8248 HH-LTO5 FC in 7226 enclosure
    • FC 8348 HH-LTO6 FC in 7226 enclosure
    • FC 8446 HH-LTO7 FC in 7226 enclosure
    • FC 8546 HH-LTO8 FC in 7226 enclosure
    • FC 8646 HH LTO-9 Fibre Channel in 7226 enclosure
  • FC EN1N (CCIN 2CFD) 64 Gb 2-port Fibre Channel (Native or NPIV VIOS support) This adapter does not support direct attach to tape.  Supported on server models: 9080-HEU, 9824-22A, 9824-42A, 9856-22H, 9856-42H
    • 3584 (TS4500) with Fibre Channel LTO10, 3592-60F (TS1160), or 3592-70F (TS1170) drives.
    • 3555/5544 (TS4300) with Fibre Channel LTO10 drives
    • Diamondback tape library with Fibre Channel LTO10 drives.
    • 3592-70F (TS1170) rack-mount drives
  • FC EN1P (CCIN 2CFD) 64 Gb LP 2-port Fibre Channel (Native or NPIV VIOS support) This adapter does not support direct attach to tape.  Supported on server models: 9080-HEU, 9824-22A, and 9856-22H
    • 3584 (TS4500) with Fibre Channel LTO10, 3592-60F (TS1160), or 3592-70F (TS1170) drives
    • 3555/5544 (TS4300) with Fibre Channel LTO10 drives
    • Diamondback tape library with Fibre Channel LTO10 drives.
    • 3592-70F (TS1170) rack-mount drives
  • FC EN2L (CCIN 2F06) 32 Gb 4-port Fibre Channel (Native or NPIV VIOS support) This adapter does not support direct attach to tape except for natively attached full height LTO10 drives.  Supported on server models: 9080-HEU, 9824-22A, 9824-42A, 9856-22H, 9856-42H
    • 3555/5544 (TS4300) with Fibre Channel LTO6, LTO7, LTO8, LTO9, or LTO10 drives
    • 3573 (TS3100, TS3200) with Fibre Channel LTO5, LTO6, LTO7, or LTO8 drives
    • 3576 (TS3310) with Fibre Channel LTO5, LTO6, LTO7, or LTO8 drives
    • 3584 (TS3500) with Fibre Channel LTO5, LTO6, LTO7, or LTO8 drives
    • 3584 (TS3500) with Fibre Channel 3592-E08 (TS1150), 3592-55G (TS1155), or 3592-60G (TS1160) drives
    • 3584 (TS4500) with Fibre Channel LTO5, LTO6, LTO7, LTO8, LTO9, LTO10, 3592-EH8 (TS1150), 3592-55F (TS1155), 3592-60F (TS1160), or 3592-70F (TS1170) drives.
    • Diamondback tape library with Fibre Channel LTO9 or LTO10 drives.
    • 3592-E08 (TS1150), or 3592-70F (TS1170) rack-mount drives
    • FC 8248 HH-LTO5 FC in 7226 enclosure
    • FC 8348 HH-LTO6 FC in 7226 enclosure
    • FC 8446 HH-LTO7 FC in 7226 enclosure
    • FC 8546 HH-LTO8 FC in 7226 enclosure
    • FC 8646 HH LTO-9 Fibre Channel in 7226 enclosure
  • FC EN2M (CCIN 2F06) 32 Gb LP 4-port Fibre Channel (Native or NPIV VIOS support) This adapter does not support direct attach to tape except for natively attached full height LTO10 drives.   Supported on server models: 9080-HEU
    • 3555/5544 (TS4300) with Fibre Channel LTO6, LTO7, LTO8, LTO9, or LTO10 drives
    • 3573 (TS3100, TS3200) with Fibre Channel LTO5, LTO6, LTO7, or LTO8 drives
    • 3576 (TS3310) with Fibre Channel LTO5, LTO6, LTO7, or LTO8 drives
    • 3584 (TS3500) with Fibre Channel LTO5, LTO6, LTO7, or LTO8 drives
    • 3584 (TS3500) with Fibre Channel 3592-E08 (TS1150), 3592-55G (TS1155), or 3592-60G (TS1160) drives
    • 3584 (TS4500) with Fibre Channel LTO5, LTO6, LTO7, LTO8, LTO9, LTO10, 3592-EH8 (TS1150), 3592-55F (TS1155), 3592-60F (TS1160), or 3592-70F (TS1170) drives.
    • Diamondback tape library with Fibre Channel LTO9 or LTO10 drives.
    • 3592-E08 (TS1150), or 3592-70F (TS1170) rack-mount drives
    • FC 8248 HH-LTO5 FC in 7226 enclosure
    • FC 8348 HH-LTO6 FC in 7226 enclosure
    • FC 8446 HH-LTO7 FC in 7226 enclosure
    • FC 8546 HH-LTO8 FC in 7226 enclosure
    • FC 8646 HH LTO-9 Fibre Channel in 7226 enclosure
  • FC EN2N (CCIN 2F05) 64 Gb 2-port Fibre Channel (Native or NPIV VIOS support) This adapter does not support direct attach to tape.  Supported on server models: 9080-HEU, 9824-22A, 9824-42A, 9856-22H, 9856-42H
    • 3584 (TS4500) with Fibre Channel LTO10, 3592-60F (TS1160), or 3592-70F (TS1170) drives
    • 3555/5544 (TS4300) with Fibre Channel LTO10 drives
    • Diamondback tape library with Fibre Channel LTO10 drives
    • 3592-70F (TS1170) rack-mount drives
  • FC EN2P (CCIN 2F05) 64 Gb LP 2-port Fibre Channel (Native or NPIV VIOS support) This adapter does not support direct attach to tape.  Supported on server models: 9080-HEU, 9824-22A, and 9856-22H
    • 3584 (TS4500) with Fibre Channel LTO10, 3592-60F (TS1160), or 3592-70F (TS1170) drives
    • 3555/5544 (TS4300) with Fibre Channel LTO10 drives
    • Diamondback tape library with Fibre Channel LTO10 drives
    • 3592-70F (TS1170) rack-mount drives
USB adapters:
  • FC EC6J (CCIN 590F) LP 2-Port low-profile USB 3.0 adapter.  Supported on server models: 9080-HEU, 9824-22A
    • FC EUA5 stand-alone USB DVD drive with cable
    • FC EU03 RDX 3.0 in 7226 enclosure
    • FC EUA4 RDX USB external docking station
  • FC EC6K (CCIN 590F) 2-Port USB 3.0 adapter.  Supported on server models: 9080-HEU, 9824-22A, 9824-42A, 9856-22H, 9856-42H
    • FC EUA5 stand-alone USB DVD drive with cable
    • FC EU03 RDX 3.0 in 7226 enclosure
    • FC EUA4 RDX USB external docking station
  • Integrated CEC USB 3.0 ports (CCIN 58F8). Supported on server models:  9824-22A, 9824-42A, 9856-22H, 9856-42H
    • FC EUA5 stand-alone USB DVD drive with cable (Front USB 3.0 port only)
    • FC EU03 RDX 3.0 in 7226 enclosure
    • FC EUA4 RDX USB external docking station (External power is required)

[{"Type":"MASTER","Line of Business":{"code":"LOB68","label":"Power HW"},"Business Unit":{"code":"BU070","label":"IBM Infrastructure"},"Product":{"code":"SWG60","label":"IBM i"},"ARM Category":[{"code":"a8m3p0000006wa4AAA","label":"Removable Media"}],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.4.0;7.5.0;7.6.0"}]