Error description

  • CICS expected to receive data from an ECI client but this
    timed-out (SO_SYNC_RECEIVE_FAILURE) as none was sent. This
    leaves a residual IE client and socket connection.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICS users.                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: Socket connections accumulate when      *
    *                      TCP/IP connections are established with *
    *                      an ECI TCPIPSERVICE but no data is      *
    *                      sent.                                   *
    ****************************************************************
    A TCPIPSERVICE is installed into CICS with a PROTOCOL of ECI.
    
    A TCP/IP connection is established causing a CIEP task to be
    attached.  No data is sent to CICS so after 30 seconds a
    DFHIE1104 message is issued, exception trace point is written
    and the CIEP task terminates.  However the socket is not closed.
    
    If this happens repeatedly then a build up of socket
    connections to the TCPIPSERVICE will occur.
    

Problem conclusion

  • DFHIEIE has been updated so that the socket is closed when the
    time out occurs.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH67058

  • Reported component name

    CICS TS Z/OS V6

  • Reported component ID

    5655YA100

  • Reported release

    400

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2025-06-23

  • Closed date

    2025-08-06

  • Last modified date

    2025-08-31

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UO04418 UO04419

Modules/Macros

  • DFHIEIE
    

Fix information

  • Fixed component name

    CICS TS Z/OS V6

  • Fixed component ID

    5655YA100

Applicable component levels

  • R400 PSY UO04419

       UP25/08/07 P F508

  • R500 PSY UO04418

       UP25/08/08 P F508

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.1","Line of Business":{"code":"LOB70","label":"Z TPS"}}]

Document Information

Modified date:
31 August 2025