Error description
After an IPL, GDPS initialization fails during site table lookup when the CPC name can temporarily not be determined from the D M=CORE command output. GEOTRC message from VPCCGRPS indicates 'CPC CPC_UNKNOWN_NAME was not found within the list of ACFFQRY Processor' is observed in Netlog, along with the following error messages: GEO2985E Multiple Domains xxxxx have been found in the GEOGROUP but GDPS could not retrieve System Automation data. Check NetLog for details. GEO070E GDPS INITIALIZATION FAILED: GEOGROUP XML SYNTAX ERROR
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: GDPS Metro * **************************************************************** * PROBLEM DESCRIPTION: GDPS Metro initialization fails when D * * M=CORE returns CPC_UNKNOWN_NAME * **************************************************************** After an IPL, GDPS initialization may fail during site table lookup when the CPC name can temporarily not be determined from the D M=CORE command output.
Problem conclusion
The D M=CORE command will be tried up to 5 times at 30 second intervals until the CPC name is determined. KEYWORDS: GDPSMETRO/K
Temporary fix
Comments
APAR Information
APAR number
PH65910
Reported component name
GDPS
Reported component ID
694235B00
Reported release
460
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2025-03-29
Closed date
2025-06-16
Last modified date
2025-07-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UO03662 UO03664 UO03665
Modules/Macros
VPCCGRPS
Fix information
Fixed component name
GDPS
Fixed component ID
694235B00
Applicable component levels
R460 PSY UO03665
UP25/06/18 P F506
R470 PSY UO03664
UP25/06/18 P F506
R480 PSY UO03662
UP25/06/18 P F506
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU070","label":"IBM Infrastructure"},"Product":{"code":"SSET85","label":"GDPS (Geographically Dispersed Parallel Sysplex)"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"460","Line of Business":{"code":"LOB66","label":"Technology Lifecycle Services"}}]