A fix is available
APAR status
Closed as new function.
Error description
RTI Profiler usability and report improvements
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IBM Automatic Binary Optimizer * * (ABO) for z/OS, 2.1 and ABO for z/OS 2.1 * * Trial * **************************************************************** * PROBLEM DESCRIPTION: This new function APAR adds the * * following improvements to the RTI * * Profiler process: * * * * The ABO RTIBIND option, used to * * prepare modules for profiling, will no * * longer attempt to rebind AMODE64 * * modules. These AMODE64 modules will * * skip the RTI rebinding step and the * * following message will now be issued : * * BOZ1433S: RTIBIND is not supported for * * 64-bit module "xxxxx". Before this * * APAR attempting to use RTIBIND on * * AMODE64 would cause ABO to abend with * * the message : BOZ1430U: Unrecoverable * * "ABEND" error encountered during binder * * API "bindW": return code=16 reason * * code=0x83ff0c40. Terminating optimizer. * * * * The RTI profiler now supports programs * * that were compiled from multiple source * * files, such as COBOL modules compiled * * with the DLL,EXPORTALL option. * * * * The RTI profiler report will now * * display the name of the data sets for * * the modules found during profiling * **************************************************************** * RECOMMENDATION: Apply provided service * **************************************************************** The RTI Profiling process was improved through new usability and report enhancements.
Problem conclusion
Temporary fix
Comments
APAR Information
APAR number
PH40642
Reported component name
AUTO BINARY OPT
Reported component ID
5697AB200
Reported release
210
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-09-15
Closed date
2021-10-05
Last modified date
2021-11-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
BOZBXITA BOZEXE1 BOZJIVP BOZMSGE BOZMSGK BOZMSGT BOZOBJ1 BOZOPT BOZPA BOZPAJ BOZRIDT BOZSMF BOZSMFJ BOZSMFR BOZSRC1
Fix information
Fixed component name
AUTO BINARY OPT
Fixed component ID
5697AB200
Applicable component levels
R210 PSY UI77444
UP21/10/07 P F110
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSERQD","label":"IBM Automatic Binary Optimizer for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"210","Line of Business":{"code":"LOB70","label":"Z TPS"}}]
Document Information
Modified date: