IBM Support

PH66774: A field with a duplicated name is not returned to an OpenAPI 3 API requester.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as unreproducible in next release.

Error description

  • When two properties within different objects have the same name,
    the second property (with the duplicate name) is omitted from
    the response returned to the API requester. The HTTP status code
    for the request is 200 (OK).
    

Local fix

  • Ensure that all fields specified in the openapi.yaml document
    used when the OpenAPI 3 API requester is built have unique
    names.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of the z/OS Connect V3.0           *
    *                 oasRequester-1.0 feature for OpenAPI 3 API   *
    *                 requesters.                                  *
    ****************************************************************
    * PROBLEM DESCRIPTION: A field with a duplicated name is not   *
    *                      returned to an OpenAPI 3 API requester. *
    ****************************************************************
    When building an API requester, duplicate property names were
    not processed correctly and this resulted in the duplicated
    property being omitted from reponse.
    

Problem conclusion

Temporary fix

Comments

  • z/OS Connect has been changed to correctly process duplicated
    properties within different objects in the openapi.yaml document
    when generating the OpenAPI 3 API requester war. This allows
    multiple properties with the same name to be returned to the API
    requester.
    
    The fix for this APAR is expected to be delivered by the PTF for
    z/OS Connect V3.0.94.0 (PH66550).
    

APAR Information

  • APAR number

    PH66774

  • Reported component name

    Z/OS CONNECT EE

  • Reported component ID

    5655CE300

  • Reported release

    000

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2025-05-29

  • Closed date

    2025-06-11

  • Last modified date

    2025-06-11

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    Z/OS CONNECT EE

  • Fixed component ID

    5655CE300

Applicable component levels

[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSVVFY","label":"z\/OS Connect Enterprise Edition"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"000"}]

Document Information