Error description
Probable system crash with below stack while changing the fc adapter ODM attribute io_dma value. Example : #chdev -l fcs0 -a io_dma=2048 -U fcs0 changed KDB(0)> f pvthread+090500 STACK: Ý0002CD00¨abend_trap+000000 () Ý00081B2C¨xm_bad_free+00026C (??, ??, ??, ??) Ý001126F8¨xmfree_backend+0008F8 (000000000070EEB4, F1000B01C0000000, F00000002FF46410, 0000000000000000, 0000004500000045) Ý00111968¨xmfree_frontend+000128 (??, ??, ??) ÝF10009D5A020CC0C¨cvfc_scsi_queue_cleanup+00028C (??, ??, ??) ÝF10009D5A01D73B0¨cvfc_cfg_updt_io_dma+000250 (??, ??) ÝF10009D5A01D7CF0¨cvfc_cfg_update+0002B0 (??, ??, ??) ÝF10009D5A01E0FA8¨cvfc_config+0003E8 (??, ??)
Local fix
Problem summary
Probable system crash with below stack while changing the fc adapter ODM attribute io_dma value. Example : #chdev -l fcs0 -a io_dma=2048 -U fcs0 changed KDB(0)> f pvthread+090500 STACK: 0002CD00 abend_trap+000000 () 00081B2C xm_bad_free+00026C (??, ??, ??, ??) 001126F8 xmfree_backend+0008F8 (000000000070EEB4, F1000B01C0000000, F00000002FF46410, 0000000000000000, 0000004500000045) 00111968 xmfree_frontend+000128 (??, ??, ??) F10009D5A020CC0C cvfc_scsi_queue_cleanup+00028C (??, ??, ??) F10009D5A01D73B0 cvfc_cfg_updt_io_dma+000250 (??, ??) F10009D5A01D7CF0 cvfc_cfg_update+0002B0 (??, ??, ??) F10009D5A01E0FA8 cvfc_config+0003E8 (??, ??)
Problem conclusion
Fixed the FC driver code to avoid the crash
Temporary fix
Comments
APAR Information
APAR number
IJ54392
Reported component name
AIX V7.3
Reported component ID
5765CD300
Reported release
730
Status
CLOSED PER
HIPER
NoHIPER
Submitted date
2025-04-16
Closed date
2025-04-16
Last modified date
2025-12-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX V7.3
Fixed component ID
5765CD300
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11T","label":"AIX 7.3 HIPERS- APARs and Fixes"},"Platform":[{"code":"PF053","label":"Power Systems"}],"Version":"730","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]
Document Information
Modified date:
10 December 2025