IJ54359: NIM TAKEOVER FAILS FOR CLIENT WITH SIT INTERFACE CONFIGURED APPLIES TO AIX 7300-02

 

APAR status

  • Closed as program error.

Error description

  • The NIM takeover will fail for the client with the sit
    interface configured, error messages are as below:
    
    0042-001 m_takeover: processing error encountered on
    "client":
       awk: Field  is not correct.
     The input line number is 2.
     The source line number is 1.
    rc=175
    0042-175 c_switch_master: An unexpected result was
    returned by the "/usr/sbin/niminit" command:
    usage:
            niminit -a <attr=value>...[-v]
               -v displays detailed output for the niminit
    operation.
    

Local fix

  • Detach the sit# interface.
    

Problem summary

  • 0042-001 m_takeover: processing error encountered on
    "client":
       awk: Field  is not correct.
    The input line number is 2.
    The source line number is 1.
    rc=175
    0042-175 c_switch_master: An unexpected result was
    returned by the "/usr/sbin/niminit" command:
    usage:
            niminit -a <attr=value>... -v
               -v displays detailed output for the niminit
    operation.
    

Problem conclusion

  • exclude the sit interface when calling switch master
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ54359

  • Reported component name

    AIX V7.3

  • Reported component ID

    5765CD300

  • Reported release

    730

  • Status

    CLOSED PER

  • HIPER

    NoHIPER

  • Submitted date

    2025-04-16

  • Closed date

    2025-04-16

  • Last modified date

    2025-12-10

  • APAR is sysrouted FROM one or more of the following:

    IJ53872

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX V7.3

  • Fixed component ID

    5765CD300

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11T","label":"AIX 7.3 HIPERS- APARs and Fixes"},"Platform":[{"code":"PF053","label":"Power Systems"}],"Version":"730","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]

Document Information

Modified date:
10 December 2025