A fix is available
APAR status
Closed as program error.
Error description
If customer assemble the TCT to define terminal,they can experience DFHSM0002 A SEVERE ERROR (CODE X'0305') HAS OCCURRED IN MODULE DFHSMGF during CICS startup. PH63625 added logic to free an IDT buffer during sign-on processing and increased the length of the SNEX, but DFHSNEX macro in SDFHMAC was not updated to reflect the new length, as a result code tries to freemain the area where not correctly mapped by DFHSNEX(in customer's case,the storage belonged to other terminal's TCTTE).
Local fix
Code TCT=NO in SIT, or use a different mechanism (e.g PLT program).
Problem summary
**************************************************************** * USERS AFFECTED: All CICS users with UI99617 or UI99618 * * applied. * **************************************************************** * PROBLEM DESCRIPTION: CICS startup terminates with * * DFHSM0002 code X'0305' * * after applying a PTF for APAR PH63625. * **************************************************************** CICS start up fails when a PTF for APAR PH63625 is applied and the CICS region is running with an Assembled TCT, in this case for defining sequential terminals. This is because new code for IDT processing is using a DFHSNEX control block which is too short and is adjacent to the Assembled DFHTCTTE control block.
Problem conclusion
UI99617 UI99618 CICS has been changed to skip IDT processing for Assembled TCT terminals.
Temporary fix
Comments
APAR Information
APAR number
PH66152
Reported component name
CICS TS Z/OS V6
Reported component ID
5655YA100
Reported release
500
Status
CLOSED PER
PE
YesPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2025-04-15
Closed date
2025-05-13
Last modified date
2025-05-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UO03171 UO03172
Modules/Macros
DFHBSTS DFHDUTM DFHSNTU DFHTCDUF DFHTCRP DFHUSAD DFHUSADT DFHXSAD DFHXSADT DFHXSIS DFHXSIST DFHXSSA DFHXSSAT DFHXSSB DFHXSSBT
Fix information
Fixed component name
CICS TS Z/OS V6
Fixed component ID
5655YA100
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.