A fix is available
APAR status
Closed as new function.
Error description
NEW FUNCTION
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of RACF password phrases on z/OS 3.1 * * and higher. * **************************************************************** * PROBLEM DESCRIPTION: * * It is not possible to bypass the built- * * in password phrase syntax rules. * **************************************************************** * RECOMMENDATION: * **************************************************************** It is not possible to bypass the built- in password phrase syntax rules.
Problem conclusion
Temporary fix
Comments
The built-in password phrase syntax rules may now be bypassed by defining a profile named PHRASE.BYPASS.BUILTIN.SYNTAX.RULES in the new OPTRACF class, and activating and RACLISTing the OPTRACF class. The following z/OS 3.2 publications are updated to describe the new function. This information is also applicable for z/OS 3.1. SA232292xx z/OS Security Server RACROUTE Command Language Reference - The description of the phrase bult-in syntax rules is modified in the ADDUSER, ALTUSER, and PASSWORD commands - SETROPTS LIST examples are updated to display the new output lines at the bottom of the PASSWORD PROCESSING OPTIONS section GA320885xx z/OS Security Server RACROUTE Data Areas - The RCVT area is updated to contain the new RCVTPSYN bit SA232298xx z/OS Security Server RACF General User's Guide - The description of the phrase bult-in syntax rules is modified SA232288xx z/OS Security Server RACF Macros and Interfaces - The new OPTRACF class is added SA232289xx z/OS Security Server RACF Security Administrator's Guide - The description of the phrase bult-in syntax rules is modified - Activating the bypass feature is described SA232287xx z/OS Security Server RACF System Programmer's Guide - The list of functions requiring the RACF subsystem is updated to include bypassing phrase syntax rules SA232294xx z/OS Security Server RACROUTE Macro Reference - The descriptions of the NEWPASS and NEWPHRASE keywords of RACROUTE REQUEST=VERIFY and VERIFYX are modified For the specific topics that are updated, see the 'summary of changes' section for each of these publications.
APAR Information
APAR number
OA67750
Reported component name
RACF
Reported component ID
5752XXH00
Reported release
7E0
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / Xsystem
Submitted date
2025-04-14
Closed date
2025-10-30
Last modified date
2026-05-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ98388 UJ98390
Modules/Macros
ICHCOP02 ICHCCU00 ICHIRCVT ICHRRCDX IRRENF00 IRRRIN12 IRRZDC10 ICHCAU00 ICHCOP11 ICHCPA00 IRRE6200
| SA232292xx | GA320885xx | SA232298xx | SA232288xx | SA232294xx |
| SA232289xx | SA232287xx |
Fix information
Fixed component name
RACF
Fixed component ID
5752XXH00
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.