A fix is available
APAR status
Closed as program error.
Error description
An IDCAMS ALTER of a user catalog increased the size of the catalog VVR. The VVR did not fit anymore into the same CI in the VVDS and had to be moved. In the particular case it was an ALTER with LOG(NONE) which added an RLS cell to the VVR. When a VVCN exists in the VVDS, there are different situations where the RBAs for the catalog in either the VVCR or VVCN are not updated. These RBAs are needed to open the catalog. As a result, another ALTER for the same catalog failed to locate the catalog VVR for the data component and the catalog became inaccessible. The following messages were seen: IEC251I 205(050,007,IGG0CLHV)-132 (RC50 RSN7) IEC331I 004-31 (RC4 RSN31) IEC161I 004-080 (RC4 RSN80) ANALYSIS: Looks like when a VVR is moved, the RBA values are not immediately updated in a normal case but the next OPEN should update them. 1) When it is moved to a different place before the VVCN and the catalog name is in the VVCR, the next open will update the RBAs in the VVCR and the open proceeds. 2) When it is moved to a different place before the VVCN and the catalog name is in the VVCN, the next open fails. 3) When it is moved to a different place after the VVCN and the catalog name is in the VVCR, the next open fails. 4) When it is moved to a different place after the VVCN and the catalog name is in the VVCN, the next open fails. KNOWN IMPACT: Catalog becomes inaccessible CATKEYS: CAT2023 CATVVDS CATALLOC CATRLS IDCALTER
Local fix
BYPASS/CIRCUMVENTION: Before the ALTER take a DSS PRINT of the VVDS of the catalog volume and ensure that the CI which contains the Catalog VVR does not contain any other data. RECOVERY ACTION: IBM support may provide a zap to correct the RBA values. If the zap does not work, restore the catalog from a backup.
Problem summary
**************************************************************** * USERS AFFECTED: All Catalog user HDZ2250 and above. * **************************************************************** * PROBLEM DESCRIPTION: An IDCAMS ALTER of a user catalog * * increased the size of the * * catalog VVR. The VVR did not fit * * anymore into the same CI in the * * VVDS and had to be moved. In the * * particular case it was an ALTER * * with LOG(NONE) which added an RLS * * cell to the VVR. * * * * When a VVCN exists in the VVDS, there * * are different situations * * where the RBAs for the catalog in * * either the VVCR or VVCN are * * not updated. These RBAs are needed to * * open the catalog. * * * * As a result, another ALTER for the * * same catalog failed to locate * * * * the catalog VVR for the data component * * and the catalog became * * inaccessible. * * * * The following messages were seen: * * * * IEC251I 205(050,007,IGG0CLHV)-132 * * (RC50 RSN7) * * IEC331I 004-31 (RC4 RSN31) * * IEC161I 004-080 (RC4 RSN80) * **************************************************************** * RECOMMENDATION: Apply PTF * **************************************************************** See Error Description.
Problem conclusion
Catalog VVDS code was modified to rectify the issue.
Temporary fix
Comments
APAR Information
APAR number
OA65715
Reported component name
ICF CATALOG & I
Reported component ID
5695DF105
Reported release
250
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-10-24
Closed date
2025-05-16
Last modified date
2025-07-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ97166 UJ97168 UJ97191
Modules/Macros
IGG0CLFJ IGG0CLKV
Fix information
Fixed component name
ICF CATALOG & I
Fixed component ID
5695DF105
Applicable component levels
R250 PSY UJ97166
UP25/06/26 P F506
R310 PSY UJ97168
UP25/06/26 P F506
R320 PSY UJ97191
UP25/06/26 P F506
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"250"}]
Document Information
Modified date:
02 July 2025