Error description
The IDCDOUT macro in SYS1.MACLIB contains wrong definitions for a certain number of fields. For example DCUTMSTP DS 1CL0008 TIMESTAMP FIELD This timestamp field is defined as 8 characters instead of a hexadecimal value as it should be. The fields are filled correctly by the IDCAMS DCOLLECT function. But programs may fail which want to use assemble the IDCDOUT macro and rely on correct field definitions.
Local fix
Create a copy of the IDCDOUT member and modify the field definitions as needed.
Problem summary
Problem conclusion
Temporary fix
Comments
IBM may address this requirement in a future release. In the meantime, users are advised to create a copy of the IDCDOUT member and modify the field definitions as needed.