APAR status
Closed as program error.
Error description
Mmvdisk will not generate the nsd stanza properly when the failuregroups option is used, causing no thin inodes created.
Local fix
Problem summary
Mmvdisk will not generate the nsd stanza properly when the failuregroups option is used, causing no thin inodes created.
Problem conclusion
This problem is fixed in 5.1.9.9 To see all Spectrum Scale APARs and their respective Fix solutions refer to page: https://public.dhe.ibm.com/storage/spectrumscale/spectrum_scale _apars.html Benefits of the solution: Fix will generate the nsd stanza file properly and assign thin inodes to the corresponding pools Work Around: None Problem trigger: Using mmvdisk fs create with failuregroups option where thin inodes are expected to be created Symptom: Lack of thin inodes on the expected pools Platforms affected: all Functional Area affected: GNR Customer Impact: High Importance
Temporary fix
Comments
APAR Information
APAR number
IJ53743
Reported component name
SPEC SCALE STD
Reported component ID
5737F33AP
Reported release
519
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2025-02-27
Closed date
2025-04-01
Last modified date
2025-04-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SPEC SCALE STD
Fixed component ID
5737F33AP
Applicable component levels
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"STXKQY"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Line of Business":{"code":"LOB69","label":"Storage TPS"}}]
Document Information
Modified date:
01 April 2025