IBM Support

IJ53723: SSD IS INCORRECTLY IDENTIFIED AS HDD

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • When create a RG or resize a RG with new IO nodes,  SSDs
    might be identified as HDD incorrectly.
    
    #/usr/lpp/mmfs/bin/mmvdisk rg resize --rg rg_1
    mmvdisk: Obtaining pdisk information for recovery group
    'rg_1'.
    mmvdisk: Analyzing disk topology for node 'node5.com'.
    mmvdisk: Analyzing disk topology for node 'node6.com'.
    mmvdisk: Analyzing disk topology for node 'node7.com'.
    mmvdisk: Validating existing pdisk locations for recovery
    group 'rg_1'.
    mmvdisk: The resized server disk topology is 'ECE 6
    SSD/NVMe and 34 HDD'.
    mmvdisk: Validating declustered arrays for recovery group
    'rg_1'.
    mmvdisk: Adding new pdisks to recovery group 'rg_1'.
    mmvdisk: Successfully resized recovery group 'rg_1'.
    
    # /usr/lpp/mmfs/bin/mmvdisk rg list --da
                    declustered   needs
             capacity             pdisks
    recovery group     array     service  type  BER      trim
     total raw free raw free%  total spare  background task
    --------------  -----------  -------  ----  -------  ----
     --------- -------- -----  ----- -----  ---------------
    rg_1            DA1          no       HDD   enable   no
      1807 TiB  903 TiB   50%    102     2  scrub (0%)
    rg_1            DA2          no       NVMe  enable   no
        75 TiB   60 TiB   80%     12     1  scrub (0%)
    rg_1            DA3          no       HDD   enable   no
      4434 GiB 4434 GiB  100%      6     1  inactive (0%)
    
    
    Reported in: 5.1.9
    

Local fix

Problem summary

  • Under certain condition when SED discovery command fails for a
    pdisk with EIO error, in those scenarios hardware type
    information is not set correctly in pdisk. Which results in
    showing SSD disk as HDD.
    

Problem conclusion

  • This problem is fixed in 5.1.9.9
    To see all Spectrum Scale APARs and their respective
    Fix solutions refer to page: 
    https://public.dhe.ibm.com/storage/spectrumscale/spectrum_scale
    _apars.html
    
    Benefits of the solution:
    Fixed issue where even if SED discovery fails for a disk,
    hardware type information is set correctly.
    
    Work Around:
    None
    
    Problem trigger:
    If SED discovery command fails for a pdisk with EIO error, in
    those scenarios hardware type information is not set correctly
    in pdisk
    
    Symptom:
    Wrong hardware type is set for a disk.
    
    Platforms affected:
    All supported platform
    
    Functional Area affected:
    GNR
    
    Customer Impact:
    severe
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ53723

  • Reported component name

    SPEC SCALE DME

  • Reported component ID

    5737F34AP

  • Reported release

    519

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2025-02-26

  • Closed date

    2025-04-01

  • Last modified date

    2025-04-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    SPEC SCALE DME

  • Fixed component ID

    5737F34AP

Applicable component levels

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"STXKQY"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Line of Business":{"code":"LOB69","label":"Storage TPS"}}]

Document Information

Modified date:
01 April 2025