Security Bulletin
Summary
There are multiple vulnerabilities in the OpenSSL library used by IBM Sterling Connect:Direct for HP NonStop. IBM Sterling Connect:Direct for HP NonStop has addressed the applicable CVEs.
Vulnerability Details
CVEID: CVE-2022-4304
DESCRIPTION: A timing based side channel exists in the OpenSSL RSA Decryption implementation
which could be sufficient to recover a plaintext across a network in a
Bleichenbacher style attack. To achieve a successful decryption an attacker
would have to be able to send a very large number of trial messages for
decryption. The vulnerability affects all RSA padding modes: PKCS#1 v1.5,
RSA-OEAP and RSASVE.
For example, in a TLS connection, RSA is commonly used by a client to send an
encrypted pre-master secret to the server. An attacker that had observed a
genuine connection between a client and a server could use this flaw to send
trial messages to the server and record the time taken to process them. After a
sufficiently large number of messages the attacker could recover the pre-master
secret used for the original connection and thus be able to decrypt the
application data sent over that connection.
CWE: CWE-203: Observable Discrepancy
CVSS Source: IBM X-Force
CVSS Base score: 5.9
CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N)
CVEID: CVE-2023-0215
DESCRIPTION: The public API function BIO_new_NDEF is a helper function used for streaming
ASN.1 data via a BIO. It is primarily used internally to OpenSSL to support the
SMIME, CMS and PKCS7 streaming capabilities, but may also be called directly by
end user applications.
The function receives a BIO from the caller, prepends a new BIO_f_asn1 filter
BIO onto the front of it to form a BIO chain, and then returns the new head of
the BIO chain to the caller. Under certain conditions, for example if a CMS
recipient public key is invalid, the new filter BIO is freed and the function
returns a NULL result indicating a failure. However, in this case, the BIO chain
is not properly cleaned up and the BIO passed by the caller still retains
internal pointers to the previously freed filter BIO. If the caller then goes on
to call BIO_pop() on the BIO then a use-after-free will occur. This will most
likely result in a crash.
This scenario occurs directly in the internal function B64_write_ASN1() which
may cause BIO_new_NDEF() to be called and will subsequently call BIO_pop() on
the BIO. This internal function is in turn called by the public API functions
PEM_write_bio_ASN1_stream, PEM_write_bio_CMS_stream, PEM_write_bio_PKCS7_stream,
SMIME_write_ASN1, SMIME_write_CMS and SMIME_write_PKCS7.
Other public API functions that may be impacted by this include
i2d_ASN1_bio_stream, BIO_new_CMS, BIO_new_PKCS7, i2d_CMS_bio_stream and
i2d_PKCS7_bio_stream.
The OpenSSL cms and smime command line applications are similarly affected.
CWE: CWE-416: Use After Free
CVSS Source: IBM X-Force
CVSS Base score: 7.5
CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H)
CVEID: CVE-2023-0286
DESCRIPTION: There is a type confusion vulnerability relating to X.400 address processing
inside an X.509 GeneralName. X.400 addresses were parsed as an ASN1_STRING but
the public structure definition for GENERAL_NAME incorrectly specified the type
of the x400Address field as ASN1_TYPE. This field is subsequently interpreted by
the OpenSSL function GENERAL_NAME_cmp as an ASN1_TYPE rather than an
ASN1_STRING.
When CRL checking is enabled (i.e. the application sets the
X509_V_FLAG_CRL_CHECK flag), this vulnerability may allow an attacker to pass
arbitrary pointers to a memcmp call, enabling them to read memory contents or
enact a denial of service. In most cases, the attack requires the attacker to
provide both the certificate chain and CRL, neither of which need to have a
valid signature. If the attacker only controls one of these inputs, the other
input must already contain an X.400 address as a CRL distribution point, which
is uncommon. As such, this vulnerability is most likely to only affect
applications which have implemented their own functionality for retrieving CRLs
over a network.
CWE: CWE-843: Access of Resource Using Incompatible Type ('Type Confusion')
CVSS Source: IBM X-Force
CVSS Base score: 8.2
CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H)
Affected Products and Versions
| Affected Product(s) | Version(s) |
| Sterling Connect:Direct for HP NonStop | 3.6 |
Remediation/Fixes
| V.R.M.F | APAR | Remediation/First Fix |
| 3.6.0.6 | NA | 3.6.0.6 iFix000, available on Fix Central |
Workarounds and Mitigations
None
Get Notified about Future Security Bulletins
References
Acknowledgement
Change History
28 Mar 2025: Initial Publication
*The CVSS Environment Score is customer environment specific and will ultimately impact the Overall CVSS Score. Customers can evaluate the impact of this vulnerability in their environments by accessing the links in the Reference section of this Security Bulletin.
Disclaimer
According to the Forum of Incident Response and Security Teams (FIRST), the Common Vulnerability Scoring System (CVSS) is an "industry open standard designed to convey vulnerability severity and help to determine urgency and priority of response." IBM PROVIDES THE CVSS SCORES ""AS IS"" WITHOUT WARRANTY OF ANY KIND, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. CUSTOMERS ARE RESPONSIBLE FOR ASSESSING THE IMPACT OF ANY ACTUAL OR POTENTIAL SECURITY VULNERABILITY. In addition to other efforts to address potential vulnerabilities, IBM periodically updates the record of components contained in our product offerings. As part of that effort, if IBM identifies previously unidentified packages in a product/service inventory, we address relevant vulnerabilities regardless of CVE date. Inclusion of an older CVEID does not demonstrate that the referenced product has been used by IBM since that date, nor that IBM was aware of a vulnerability as of that date. We are making clients aware of relevant vulnerabilities as we become aware of them. "Affected Products and Versions" referenced in IBM Security Bulletins are intended to be only products and versions that are supported by IBM and have not passed their end-of-support or warranty date. Thus, failure to reference unsupported or extended-support products and versions in this Security Bulletin does not constitute a determination by IBM that they are unaffected by the vulnerability. Reference to one or more unsupported versions in this Security Bulletin shall not create an obligation for IBM to provide fixes for any unsupported or extended-support products or versions.