Troubleshooting
Problem
Deploying a VM fails.
VM is in error status.
When deploying from powervc web console, you may see this error
Deploy of virtual machine vm-name on host hostname failed with exception: Build of instance vm-id aborted: Failure prepping block device.
Cause
Storage Firmware is being updated.
Diagnosing The Problem
Cinder logs may show the following error:
'CMMVC5772E The operation requested could not be performed because an update is in progress.\n'
Resolving The Problem
- Place the hosts assigned to storage controller in maintenance mode.
- Unmanage the storage controller being updated prior to the firmware update. This option has a longer recovery time, due to time it takes to re-manage the storage array.
- Consider upvoting this feature request for adding a maintenance mode for storage arrays: https://ideas.ibm.com/ideas/PVC-I-511
Document Location
Worldwide
[{"Type":"MASTER","Line of Business":{"code":"LOB68","label":"Power HW"},"Business Unit":{"code":"BU070","label":"IBM Infrastructure"},"Product":{"code":"SS2MT9","label":"PowerVC"},"ARM Category":[{"code":"a8m50000000L0hqAAC","label":"PowerVC Storage"}],"ARM Case Number":"TS018797009","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"All Versions"}]