IBM Support

Updating the Maximo Asset Management IoT file

General Page

If you are installing Maximo Asset Health Insights 7.6.0.4 on Maximo Asset Management 7.6.1, you must also update the IoT7601 file. The IoT7601 file is attached to this tech note.

 

 

Once you have installed Maximo Asset Management 7.6.1 and Maximo Asset Health Insights 7.6.0.4, take the following actions:

Procedure

  1. Ensure that no database configuration changes are pending.
  2. Shut down the Maximo application server.
  3. Back up the database.
  4. Back up the Maximo directory.
  5. Extract the files into the install_home folder and select the Overwrite existing files and the Use folder names options.
  6. Run the updatedb.bat utility to run all the interim fix database scripts:
    1. At a DOS prompt, change the directory to install_home\tools\maximo, for example, c:\IBM\SMP\maximo\tools\maximo.
    2. Run updatedb.bat.
    3. Run configdb.bat.
  7. Delete the application server cache, for example:
    • Oracle WebLogic Server: BEA_Root\user_projects\domains\mydomain\MAXIMOSERVER\.wlnotdelete
    • IBM WebSphere® Application Server: WebSphere_Root\AppServer\profiles\Custom01\temp\machinenameNode01\MAXIMOSERVER
  8. Delete the browser cache on every computer that uses the product.
  9. Rebuild and redeploy the EAR files.
  10. Rebuild and redeploy the maximo-x.war file.
  11. Restart the application server.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSXQ46","label":"IBM Maximo Asset Health Insights"},"Component":"","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.6.0.4","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
09 August 2018

UID

ibm10719699