PH65702: COMMAND INCORRECTLY PROCESSED WHEN F3 PRESSED AND COMMAND LINE NON-BLANK

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When the command line is non-blank and a PF key is pressed,
    the command line is processed as an operand of the command
    defined by the PF key.
    However, when F3 is pressed (END), the command line is being
    processed prior to the END command. This results in the command
    being issued but it should not be.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of SDSF V2R5 and 3.1               *
    ****************************************************************
    * PROBLEM DESCRIPTION: Command incorrectly processed when F3   *
    *                      pressed and command line non-blank      *
    ****************************************************************
    When the command line is non-blank and a PF key is pressed, the
    command line is processed as an operand of the command defined
    by the PF key. However, when F3 is pressed (END), the command
    line is being processed prior to the END command. This results
    in the command being issued but it should not be.
    

Problem conclusion

  • SDSF V2R5 and 3.1 have been updated to restrict non-blank
    command being processed as an operand prior to the END command
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH65702

  • Reported component name

    SDSF

  • Reported component ID

    566548801

  • Reported release

    7D0

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2025-03-18

  • Closed date

    2025-05-13

  • Last modified date

    2025-05-19

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UO03169 UO03170

Modules/Macros

  • HSFIDSP
    

Fix information

  • Fixed component name

    SDSF

  • Fixed component ID

    566548801

Applicable component levels

  • R7D0 PSY UO03170

       UP25/05/17 I 1000

  • R7E0 PSY UO03169

       UP25/05/17 I 1000

Fix is available