Question & Answer
Question
Why are messages like these seen in the SYSLOG or the controller EQQMLOG:
STCnnnnn EQQZ024I =ZMAIN RMDEL2 & E9D4C1C9 D540D9D4 C4C5D3F2 00000050
STCnnnnn lS 000193E2 00000000 00000000 00000000
STCnnnnn lS 000193E2 00000000 00000000 00000000
where nnnnn is the started task number of the controller?
Cause
PH65224
Answer
The purpose of PH65224 is to prevent the z Workload Scheduler RM ( resource manager ) from being added to an initiator ( INIT ) ASID.
Unpredictable results may be seen if there is a zWS RM active on an INIT ASID, and this initiator is cancelled.
The zWS RM should only be added for local dialog ASIDs.
Should a RC greater than 4 be detected by the PH65224 code, messages like this will be written to the SYSLOG:
STCnnnnn EQQZ024I =ZMAIN RMDEL2 & E9D4C1C9 D540D9D4 C4C5D3F2 00000050
STCnnnnn lS 000193E2 00000000 00000000 00000000
STCnnnnn lS 000193E2 00000000 00000000 00000000
On the left the translated ASCII data, on the right the HEX dump content of the data.
The component structure of this WTO message issued by the Controller started task is:
EQQZ024I Description ASID TOKEN RC FILLER
in the above example the Resource Manager Delete message contains:
Description= ZMAIN RMDEL2 (issued by EQQZMAIN, label RMDEL2) (E9D4C1C9 D540D9D4 C4C5D3F2)
ASID = x'50' (00000050)
TOKEN = x'000193E2' (000193E2)
RC = x'00000000' (00000000)
FILLER = x'0000000000000000' (00000000 00000000)
ASID = x'50' (00000050)
TOKEN = x'000193E2' (000193E2)
RC = x'00000000' (00000000)
FILLER = x'0000000000000000' (00000000 00000000)
If messages like these are seen in the SYSLOG please open a case for z Workload Scheduler support and include the
SYSLOG and the controller EQQMLOG.
[{"Type":"MASTER","Line of Business":{"code":"LOB70","label":"Z TPS"},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSWL3F","label":"IBM Z Workload Scheduler"},"ARM Category":[{"code":"a8m0z0000001fyAAAQ","label":"ZOS-\u003EIZWS-\u003EINSTALLATION"}],"ARM Case Number":"TS000000000","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"All Versions"}]