IBM Support

IJ53687: SSPDB IS MISSING(SNAP SVCOLLECT IN PADMIN):PG_VERSION NOT EXIST

 

APAR status

  • Closed as program error.

Error description

  • In VIOS 4.1, collecting snap svCollect in padmin doesn't
    collect SSP DB.
    
    svCollect (dbCollect script) fails to check below file
    and exit :
    /var/vio/SSP/<CLusterName>/D_E_F_A_U_L_T_061310/VIOSCFG/D
    B/PG/PG_VERSION not exist
    

Local fix

  • run snap svCollect or snap -ac from oem_setup_env
    

Problem summary

  • snap svCollect on VIOS 4.1 does not collect the SSP DB
    

Problem conclusion

  • Correct check of db type in snap scripts so that we correctly
    collect the SSP DB if it exists.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ53687

  • Reported component name

    AIX V7.3

  • Reported component ID

    5765CD300

  • Reported release

    730

  • Status

    CLOSED PER

  • HIPER

    NoHIPER

  • Submitted date

    2025-02-24

  • Closed date

    2025-02-24

  • Last modified date

    2025-02-24

  • APAR is sysrouted FROM one or more of the following:

    IJ53590

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX V7.3

  • Fixed component ID

    5765CD300

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11T","label":"AIX 7.3 HIPERS- APARs and Fixes"},"Platform":[{"code":"PF053","label":"Power Systems"}],"Version":"730","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]

Document Information

Modified date: