IBM Support

PH65080: COMMAND=BROWSE NO LONGER WORKING

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The Optim command line interface, also used by BMC and ADB,
    stopped working for a table with a schema length of > 8
    characters or table name of > 18 characters.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Optim users utilizing the Optim command  *
    *                 line interface.                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: See Error Description.                  *
    ****************************************************************
    Optim is incorrectly determining the DB2 release on which
    it is being executed and aborts processing due to a check of
    the length of the <schema>.<table_name> values.
    

Problem conclusion

  • Optim processing will be corrected.
    

Temporary fix

Comments

  • ×**** PE25/03/05 FIX IN ERROR. SEE APAR PH65538  FOR DESCRIPTION
    

APAR Information

  • APAR number

    PH65080

  • Reported component name

    OPTIM MOVE FOR

  • Reported component ID

    5655V0700

  • Reported release

    B70

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2025-01-31

  • Closed date

    2025-03-03

  • Last modified date

    2025-04-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UO02306

Modules/Macros

  • FOP1OSFN FOP2RRSQ FOP9APIM FOPCFPMN FOPHSTM  FOPK00   FOPK06
    FOPK12   FOPMADDE FOPMAIN  FOPMAMAI FOPMARCN FOPMCBMN FOPMCMAI
    FOPMCOLP FOPMDDDL FOPMDPRC FOPMDXTR FOPMECMN FOPMEMAI FOPMIXMM
    FOPMMCMR FOPMMJBS FOPMMUNU FOPMMUTL FOPMSELM FOPMUXIM FOPOMN
    FOPRS10  FOPRS3   FOPRS4   FOPRS9   FOPZFBMN FOPZFMMN FOPZMAIN
    

Fix information

  • Fixed component name

    OPTIM MOVE FOR

  • Fixed component ID

    5655V0700

Applicable component levels

  • RB70 PSY UO02306

       UP25/04/02 P F503

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"B70"}]

Document Information

Modified date:
02 April 2025