IBM Support

IJ53183: I/O FAILURE OCCURS WHEN GW NODE FAILOVER HAPPENS

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • On Gateway node shutdown, Gateway node forcefully returns EIO to
    the application node which is promptly passing on to the
    application triggering the Read operation.
    

Local fix

Problem summary

  • On Gateway node shutdown, Gateway node forcefully returns EIO to
    the application node which is promptly passing on to the
    application triggering the Read operation.
    

Problem conclusion

  • This problem is fixed in 5.2.2.1
    To see all Spectrum Scale APARs and their respective
    Fix solutions refer to page: 
    https://public.dhe.ibm.com/storage/spectrumscale/spectrum_scale
    _apars.html
    
    Benefits of the solution:
    App node doesn't see Gateway node failure/failover happening in
    the background and Read requests are continuously served.
    
    Work Around:
    None
    
    Problem trigger:
    Trigger Read on large 2GB file from app node and when read is in
    progress, mmshutdown the Gateway node..
    
    Symptom:
    IO Error
    
    Platforms affected:
    Linux Only
    
    Functional Area affected:
    AFM
    
    Customer Impact:
    High Importance
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ53183

  • Reported component name

    SPEC SCALE STD

  • Reported component ID

    5737F33AP

  • Reported release

    522

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2024-12-13

  • Closed date

    2025-01-31

  • Last modified date

    2025-01-31

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    SPEC SCALE STD

  • Fixed component ID

    5737F33AP

Applicable component levels

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"STXKQY"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"522","Line of Business":{"code":"LOB69","label":"Storage TPS"}}]

Document Information

Modified date:
31 January 2025