IBM Support

OA67421: ZCTMR040 PRODUCES FALSE FINDINGS, DUE TO TWO IOAENV RECORDS FOUND

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Investigation showed that two IOAENV records exist, it caused
    the failure due to one of the records not having all the fields.
    
    This caused the compliance check to fail, due to the missing
    fields in the one record.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of zSecure Audit exploiting STIG RACF  *
    *                 compliance control ZCTMR040.                 *
    ****************************************************************
    * PROBLEM DESCRIPTION: zSecure Audit's STIG RACF compliance    *
    *                      control ZCTMR040 might report incorrect *
    *                      non-compliant results.                  *
    ****************************************************************
    * RECOMMENDATION: Apply the PTF provided.                      *
    ****************************************************************
    When the BMC IOA Gateway Monitor component is active, the
    zSecure Audit's STIG RACF compliance control ZCTMR040 (BMC
    Control-M configuration/parameter values must be properly
    specified) reports non-compliant findings.
    

Problem conclusion

  • zSecure Audit has been modified, so that its STIG RACF
    compliance control ZCTMR040 does not report incorrect
    non-compliant findings in cases where the BMC IOA Gateway
    Monitor component is active.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA67421

  • Reported component name

    ZSEC BASE,ADMIN

  • Reported component ID

    5655T0100

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2025-01-17

  • Closed date

    2025-02-07

  • Last modified date

    2025-03-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UJ96631

Modules/Macros

  • CKAHCM40
    

Fix information

  • Fixed component name

    ZSEC BASE,ADMIN

  • Fixed component ID

    5655T0100

Applicable component levels

  • R310 PSY UJ96631

       UP25/02/08 P F502

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSPQTM","label":"IBM Security zSecure Admin"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310","Line of Business":{"code":"LOB70","label":"Z TPS"}}]

Document Information

Modified date: