IBM Support

OA67373: BPXUNVFS ABEND0C4 UFS READONLY NO UPPERDIR RELATIVE LOWERDIR PATH CLIENT MOUNT FAILURE RC9D RSN102300B7

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • User hit the following ABEND0C4 on two images when running some
    workloads.
    
     DUMP TITLE=COMPON=BPX,COMPID=SCPX1,ISSUER=BPXMIPCE,MODULE=BPXUN
               VFS+00016ACE,ABEND=S00C4,REASON=00000004
    
    Also mount failures RC9D RSN102300B7 are seen from D OMVS,MF
    outputs:
    
     TIME=14.37.58  DATE=2024/11/26        MOUNT RC=009D
    RSN=102300B7
       NAME=*UFS0002317D
       TYPE=UFS
    PATH=b549dcaed099eaa674e7325d8aa221f6fdcc8b7a907497eb96a25/merge
    d
    PARM=,lowerdir=9:11:12:13:14:15:16:17:18:19:20:21:22:23:24:25,me
    t
    
    VERIFICATION STEPS:
    1) ABEND0C4 occurred in module BPXUNVFS on the client system in
    shared filesystem configuration when a UFS file system is being
    mounted
    2) The UFS file system being mounted was readonly
    3) User did not specify upperdir keyword in the mount parameters
    4) User used relative path for lowerdir in the mount parameters
    
    Example of the mount command:
    mount -t ufs -r -o 'workdir=w,lowerdir=l' mnt
    
    
    
    FIXCAT KEYWORD:
    ZOSCP/K
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users of z/OS UNIX System Services for                   *
    * HBB77D0 HBB77E0 using union file system                      *
    * in the shared filesystem configuration                       *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * ABEND0C4 may occur on the client                             *
    * system when attempting to mount                              *
    * a union file system in the shared                            *
    * filesystem configuration. Abend                              *
    * happens when the following conditions                        *
    * are met:                                                     *
    * - Mount the union file system readonly                       *
    * - Keyword 'upperdir' is not specified                        *
    * - Use relative path for the lowerdir                         *
    *   directory                                                  *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    When the keyword 'upperdir' is not specified, readonly union
    file system mount processing has no upper directory to use. It
    needs to use the first lowerdir directory as the first merged
    directory. Since union file system mount point is inaccessible
    on the client system, the pointer of the lowerdir directory is
    null. Accessing null pointer causes abend on the client system
    

Problem conclusion

  • Check the pointer of the lowerdir directory for null before
    using it.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA67373

  • Reported component name

    OPENMVS SYS SRV

  • Reported component ID

    5695SCPX1

  • Reported release

    7E0

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2025-01-08

  • Closed date

    2025-03-10

  • Last modified date

    2025-04-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UJ96777 UJ96778

Modules/Macros

  • BPXUNVFS
    

Fix information

  • Fixed component name

    OPENMVS SYS SRV

  • Fixed component ID

    5695SCPX1

Applicable component levels

  • R7D0 PSY UJ96778

       UP25/03/26 P F503

  • R7E0 PSY UJ96777

       UP25/03/26 P F503

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19O"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"7E0"}]

Document Information

Modified date:
02 April 2025